System Specifications

A

Table A-1ERX specifications

 

ERX-1400 Series

ERX-700 Series

Weight

 

 

Chassis only

42 lb (18.9 kg)

22 lb (9.9 kg)

Chassis fully configured

88 lb (39.6 kg)

46 lb (20.7 kg)

 

 

 

Dimensions

22.75 (H) x 19 (W) x 16 (D) inches

10.5 (H) x 19 (W) x 16 (D) inches

 

(57.78 x 48.26 x 40.64 cm)

(26.67 x 48.26 x 40.64 cm)

Environmental Requirements

(NEBS GR-63-CORE compliant)

 

Ambient operating temperature

Long term: 41° to 104° F (5° to 40° C)

 

 

Short term: 23° to 122° F (-5°to 50° C)

 

Ambient operating humidity

Long term: 5% to 85% (noncondensing)

 

 

Short term: 5% to 95% (noncondensing)

 

Ambient storage temperature

–40°to 158° F (–40°to +70° C), 95% relative humidity

Ambient storage humidity

5% to 95% (noncondensing)

 

 

 

 

Heat Dissipation

2400 W, 8190 BTU/hour maximum

1400 W, 4780 BTU/hour maximum

Space Requirements

• 3 feet (90 cm) behind system or

• 3 feet (90 cm) behind system or

 

rack

rack

 

• No space requirements for sides of

• Do not block air vents on sides of

 

units or rack

the system.

 

• Do not block air vents on front or

• Do not place equipment that

 

back of the system.

exhausts hot air to right of the

 

 

system.

• Be aware that system exhausts hot air from its left side.

• Allow at least 18 inches (45 cm) at side of the unit or rack.

Page 119