Performance Specifications ERX Edge Routers

B-5

Table B-2Performance specifications for module assemblies (continued)

Name

Capability

Redundancy Support

Power Use

cOC12/STM4 F0

OC12/STM4

1:N redundancy

130 W

(single mode and multimode,

OC3/STM1

SONET APS redundancya

 

multimode with and without

DS3

 

 

 

SONET APS redundancy)

 

 

 

T1, E1

 

 

 

 

 

 

 

 

DS0

 

 

 

 

HDLC Framing

 

 

 

 

 

 

 

CT1

DS1, DS0

1:N redundancy

40 W

 

HDLC Framing

 

 

 

 

 

 

 

CT3

DS3, DS1, DS0

1:N redundancy

60 W

 

HDLC Framing

 

 

 

 

 

 

 

CT3 12 F0

DS3, DS1, DS0

1:N redundancy

130 W

 

HDLC Framing

 

 

 

 

 

 

 

E3 ATM

ATM/AAL5

1:N redundancy

60 W

 

 

 

 

E3 FRAME

E3

1:N redundancy

60 W

(3 ports)

HDLC Framing

 

 

 

 

 

 

 

E3 FRAME

E3

N/A

135 W

(12 ports)

HDLC Framing

 

 

 

 

 

 

 

FE-2

Ethernet

N/A

60 W

 

(IEEE 802.3)

 

 

 

 

10/100Base-T

 

 

 

 

 

 

 

FE-8

Ethernet

N/A

130 W

 

(IEEE 802.3)

 

 

 

 

10/100Base-T

 

 

 

 

 

 

 

Gigabit Ethernet

Ethernet

Redundant port

130 W

 

(IEEE 802.3z)

 

 

 

 

1000 Base-SX

 

 

 

 

1000 Base-LH

 

 

 

 

1000 Base-ZX

 

 

 

HSSI

Up to 44.736 MHz

N/A

60 W

 

data rate

 

 

 

 

HDLC

 

 

 

 

 

 

 

IPSec Service

IPSec Tunnels

Multiple IPSec Service

130 W

 

 

modules provide redundancy

 

OC3 (dual port)

OC3c/STM1

N/A

60 W

 

ATM/AAL5

 

 

 

 

HDLC Framing

 

 

 

 

 

 

 

OC3/STM1 ATM

OC3/STM-1,

1:N redundancy

130 W

(single mode and multimode)

ATM:AAL5

 

 

 

 

 

 

 

 

 

 

 

 

Page 127
Image 127