B-8APPENDIX B

Module Specifications

Table B-3Connection information for module assemblies (continued)

Assembly

Line

 

 

 

 

 

 

Name and

Module

I/O Module

No. of

 

 

 

 

Capability

Label

Label

Ports

Connector Type

Cabling Specifications

cOC3/STM1

cOCx/STMx

cOC3

4

SC full duplex

Tx power:

single mode

F0

STM1

 

 

 

min: –5.0 dBm

long reach

 

F0 I/O

 

 

 

max: 0 dBm

 

 

LONG

 

 

 

 

 

 

 

• Center wavelength: 1310 nm

 

 

HAUL

 

 

 

 

 

 

Rx input power:

 

 

 

 

 

 

 

 

 

 

 

min: –34 dBm

 

 

 

 

 

 

max: –7 dBm

 

 

 

 

 

• Fiber type: 9-micron core

 

 

 

 

 

• Rated for 40 km (24.8 miles)

 

 

 

 

 

 

of 9-micron core cable

cOC12/STM4

cOCx/STMx

cOC12

1

SC full duplex

Tx power:

multimode

F0

STM4

 

 

 

min: –19 dBm

without

 

F0 I/O

 

 

 

max: –14 dBm

 

MULTI

 

 

 

SONET APS

 

 

 

• Center wavelength: 1310 nm

redundancy

 

MODE

 

 

 

 

 

Rx input power:

 

 

 

 

 

 

 

 

 

 

 

min: –30 dBm

 

 

 

 

 

 

max: –14 dBm

 

 

 

 

 

• Rated for 2 km (1.2 miles)

 

 

 

 

 

 

over 62.5-micron core cable

 

 

 

 

 

 

with an optical loss of 0–9 dB

 

 

 

 

 

 

or 50-micron core cable with

 

 

 

 

 

 

an optical loss of 7 dB

cOC12/STM4

cOCx/STMx

COC12

1 active

SC full duplex

Tx power:

multimode

F0

F0

1 redundant

 

 

min: –19 dBm

with SONET

 

APS

 

 

 

max: –14 dBm

 

MULTI

 

 

 

APS

 

 

 

• Center wavelength: 1310 nm

redundancy

 

MODE

 

 

 

 

 

Rx input power:

 

 

 

 

 

 

 

 

 

 

 

min: –30 dBm

 

 

 

 

 

 

max: –14 dBm

 

 

 

 

 

• Rated for 2 km (1.2 miles)

 

 

 

 

 

 

over 62.5-micron core cable

with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB

Page 130
Image 130
Juniper Networks ERX-700, ERX-1410, ERX-1440, ERX-705 manual 8APPENDIX B