CHAPTER 7
Maintaining the ERX System
6When this SRP module is available, synchronize the SRP modules.
host1#synchronize
7When the SRP modules are synchronized, reboot the SRP module that you upgraded.
host1#reload slot 6
8When this SRP module is available, synchronize the SRP modules.
host1#synchronize
9When the SRP modules are synchronized, force the redundant SRP module to take over from the primary SRP module.
host1#srp switch
10Immediately remove the former primary SRP module.
11Repeat steps
Replacing an NVS Card
To replace an NVS card on an SRP module:
1Obtain an antistatic container for the NVS card you will remove (see Storing Modules and Components, earlier in this chapter).
2With a small flathead screwdriver, remove the faceplate from the NVS card slot on the SRP module (see Figure
3Use the screwdriver to depress the button next to the NVS card (see Figure
This action releases the NVS card.