7-4

CHAPTER 7

Maintaining the ERX System

6When this SRP module is available, synchronize the SRP modules.

host1#synchronize

7When the SRP modules are synchronized, reboot the SRP module that you upgraded.

host1#reload slot 6

8When this SRP module is available, synchronize the SRP modules.

host1#synchronize

9When the SRP modules are synchronized, force the redundant SRP module to take over from the primary SRP module.

host1#srp switch

10Immediately remove the former primary SRP module.

11Repeat steps 48for the former primary SRP module.

Replacing an NVS Card

To replace an NVS card on an SRP module:

1Obtain an antistatic container for the NVS card you will remove (see Storing Modules and Components, earlier in this chapter).

2With a small flathead screwdriver, remove the faceplate from the NVS card slot on the SRP module (see Figure 7-1).

3Use the screwdriver to depress the button next to the NVS card (see Figure 7-1).

This action releases the NVS card.

Page 96
Image 96
Juniper Networks ERX-1410, ERX-1440, ERX-700, ERX-705 manual Replacing an NVS Card