Connection Information ERX Edge Routers

B-13

Table B-3Connection information for module assemblies (continued)

Assembly

Line

 

 

 

 

Name and

Module

I/O Module

No. of

 

 

Capability

Label

Label

Ports

Connector Type

Cabling Specifications

 

 

 

 

 

 

GE

GE/FE

GE

1 active

SC full duplex

single modeb

 

I/O

1 redundant

 

 

 

SINGLE

 

 

 

 

MODE

 

 

Tx power

min: –11 dBm

max: –3 dBm

Center wavelength: 1300 nm

Rx input power

min: –20 dBm

max: –3 dBm

Rated for 550 m (601 yards) over 62.5-micron core or 50-micron core MM fiber

Rated for 5 km (3.1 miles) over 10-micron core cable

HSSI

HSSI-3F

HSSI-3

3

Standard HSSI

50 feet (15.24 m) maximum

 

 

 

 

connector: 2-row,

 

cable length

 

 

 

 

50-pin, receptacle

 

 

 

 

 

 

 

header with rails and

 

 

 

 

 

 

 

latch blocks

 

 

 

IPSec Service

IPSEC

No I/O

N/A

N/A

N/A

 

 

SERVICE

module

 

 

 

 

 

OC3 (dual

OC3

OC3

2

SC full duplex

Tx power:

port)

 

I/O

 

 

 

min: –19 dBm

multimode

 

MULTI

 

 

 

max: –14 dBm

 

 

MODE

 

 

• Center wavelength: 1310 nm

 

 

 

 

 

 

 

 

 

 

Rx input power:

 

 

 

 

 

 

min: –30 dBm

 

 

 

 

 

 

max: –14 dBm

 

 

 

 

 

• Rated for 2 km (1.2 miles)

 

 

 

 

 

 

over 62.5-micron core cable

 

 

 

 

 

 

with an optical loss of 0–9 dB

 

 

 

 

 

 

or 50-micron core cable with

 

 

 

 

 

 

an optical loss of 7 dB

OC3 (dual

OC3

OC3

2

SC full duplex

Tx power:

port)

 

I/O

 

 

 

min: –15 dBm

single mode

 

SINGLE

 

 

 

max: –8 dBm

 

 

 

 

 

 

 

MODE

 

 

• Center wavelength: 1310 nm

 

 

 

 

 

 

 

 

 

 

Rx input power:

 

 

 

 

 

 

min: –31 dBm

 

 

 

 

 

 

max: –8 dBm

 

 

 

 

 

• Rated for 15 km (9.3 miles) of

 

 

 

 

 

 

9-micron core cable

 

 

 

 

 

 

 

 

Page 135