B-10APPENDIX B

Module Specifications

Table B-3Connection information for module assemblies (continued)

Assembly

Line

 

 

 

 

 

Name and

Module

I/O Module

No. of

 

 

 

Capability

Label

Label

Ports

Connector Type

Cabling Specifications

CT3

CT3

CT3/T3

3

BNC

• The line interface unit

 

 

I/O

 

75 ohm

 

supports two line build-outs:

 

 

 

 

 

 

0–68.5 m (0–225 feet)

 

 

 

 

 

 

69–137 m (226–450 feet)

 

 

 

 

 

• Signal strength is software

 

 

 

 

 

 

controlled.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with ANSI

 

 

 

 

 

 

T1.102-1993: Digital

 

 

 

 

 

 

Hierarchy – Electrical

 

 

 

 

 

 

Interfaces (1999) for cable

 

 

 

 

 

 

lengths up to 201 m (660

 

 

 

 

 

 

feet).

CT3 12 F0

CT3/T3-F0

CT3/T3

12

BT43 SMB

• The line interface unit

 

 

12

 

(cable that adapts to

 

supports two line build-outs:

 

 

I/O

 

 

0–68.5 m (0–225 feet)

 

 

 

75-ohm BNC is

 

 

 

 

 

available)

 

69–137 m (226–450 feet)

 

 

 

 

 

• Signal strength is software

 

 

 

 

 

 

controlled.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with ANSI

 

 

 

 

 

 

T1.102-1993: Digital

 

 

 

 

 

 

Hierarchy – Electrical

 

 

 

 

 

 

Interfaces (1999) for cable

 

 

 

 

 

 

lengths up to 201 m (660

 

 

 

 

 

 

feet).

E3 ATM

E3 ATM

E3

3

BNC

The transmitted signal complies

 

 

I/O

 

75 ohm

with ITUT G.703:

 

 

 

 

 

Physical/electrical characteristics

 

 

 

 

 

of hierarchical digital interfaces

 

 

 

 

 

(November 2001) for cable

 

 

 

 

 

lengths from 0–137 m

 

 

 

 

 

(0–450 feet).

E3 FRAME

E3 FRAME

E3

3

BNC

The transmitted signal complies

(3 ports)

 

I/O

 

75 ohm

with ITUT G.703:

 

 

 

 

Physical/electrical characteristics

 

 

 

 

 

of hierarchical digital interfaces (November 2001) for cable lengths from 0–137 m (0–450 feet).

Page 132
Image 132
Juniper Networks ERX-1410, ERX-1440, ERX-700, ERX-705 manual 10APPENDIX B