Juniper Networks ERX-700, ERX-1410, ERX-1440, ERX-705 manual 20APPENDIX B

Models: ERX-1410 ERX-705 ERX-700 ERX-1440

1 184
Download 184 pages 51.01 Kb
Page 142
Image 142

B-20APPENDIX B

Module Specifications

Table B-3Connection information for module assemblies (continued)

Assembly

Line

 

 

 

 

 

Name and

Module

I/O Module

No. of

 

 

 

Capability

Label

Label

Ports

Connector Type

Cabling Specifications

T3 ATM

T3 ATM

CT3/T3

3

BNC

The line interface unit

(3 ports)

 

I/O

 

75 ohm

 

supports two line build-outs:

 

 

 

 

 

0–68.5 m (0–225 feet)

 

 

 

 

 

 

 

 

 

 

 

 

69–137 m (226–450 feet)

 

 

 

 

 

• Signal strength is software

 

 

 

 

 

 

controlled.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with ANSI

 

 

 

 

 

 

T1.102-1993: Digital

 

 

 

 

 

 

Hierarchy – Electrical

 

 

 

 

 

 

Interfaces (1999) for cable

 

 

 

 

 

 

lengths up to 201 m (660

 

 

 

 

 

 

feet).

T3 FRAME

T3 FRAME

CT3/T3

3

BNC

The line interface unit

(3 ports)

 

I/O

 

75 ohm

 

supports two line build-outs:

 

 

 

 

 

0–68.5 m (0–225 feet)

 

 

 

 

 

 

 

 

 

 

 

 

69–137 m (226–450 feet)

 

 

 

 

 

• Signal strength is software

 

 

 

 

 

 

controlled.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with ANSI

 

 

 

 

 

 

T1.102-1993: Digital

 

 

 

 

 

 

Hierarchy – Electrical

 

 

 

 

 

 

Interfaces (1999) for cable

 

 

 

 

 

 

lengths up to 201 m (660

 

 

 

 

 

 

feet).

T3 FRAME

COCX-F3

CT3/T3

12

BT43 SMB

The line interface unit

(12 ports)

 

12

 

(cable that adapts to

 

supports two line build-outs:

 

I/O

 

 

0–68.5 m (0–225 feet)

 

 

 

75-ohm BNC is

 

 

 

 

 

available)

 

69–137 m (226–450 feet)

 

 

 

 

 

• Signal strength is software

 

 

 

 

 

 

controlled.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with ANSI

 

 

 

 

 

 

T1.102-1993: Digital

 

 

 

 

 

 

Hierarchy – Electrical

 

 

 

 

 

 

Interfaces (1999) for cable

 

 

 

 

 

 

lengths up to 201 m (660

 

 

 

 

 

 

feet).

TSM

TUNNEL

No I/O

N/A

N/A

N/A

 

SERVICE

module

 

 

 

 

 

 

 

 

 

 

 

Page 142
Image 142
Juniper Networks ERX-700, ERX-1410, ERX-1440, ERX-705 manual 20APPENDIX B