Connection Information ERX Edge Routers

B-11

Table B-3Connection information for module assemblies (continued)

Assembly

Line

 

 

 

 

 

 

Name and

Module

I/O Module

No. of

 

 

 

 

Capability

Label

Label

Ports

Connector Type

Cabling Specifications

E3 FRAME

COCX-F3

E3-12

12

BT43 SMB

The transmitted signal complies

(12 ports)

 

FRAME

 

(cable that adapts to

with ITUT G.703:

 

 

Physical/electrical characteristics

 

 

I/O

 

75-ohm BNC is

 

 

 

of hierarchical digital interfaces

 

 

 

 

available)

 

 

 

 

(November 2001) for cable

 

 

 

 

 

 

 

 

 

 

lengths from 0–137 m

 

 

 

 

 

(0–450 feet).

FE-2

FE-2

FE-2

2

RJ-45

For 10-Mbps operation, use

 

 

I/O

 

 

 

CAT 3, 4, or 5 UTP cable.

 

 

 

 

 

• For 100-Mbps operation, use

 

 

 

 

 

 

only CAT 5 UTP cable.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with IEEE

 

 

 

 

 

 

802.3/802.3u for cable

 

 

 

 

 

 

lengths up to 100 m

 

 

 

 

 

 

(328 feet).

FE-8

GE/FE

FE-8

8

RJ-45

For 10-Mbps operation, use

 

 

I/O

 

 

 

CAT 3, 4, or 5 UTP cable.

 

 

 

 

 

• For 100-Mbps operation, use

 

 

 

 

 

 

only CAT 5 UTP cable.

 

 

 

 

 

The transmitted signal

 

 

 

 

 

 

complies with IEEE

 

 

 

 

 

 

802.3/802.3u for cable

 

 

 

 

 

 

lengths up to 100 m

 

 

 

 

 

 

(328 feet).

GE

GE/FE

GE

1 active

LC full duplex

Tx power

1000 Base-SX

 

I/O

1 redundant

 

 

min: –9.5 dBm

 

 

SFPa

 

 

 

max: –4 dBm

 

 

 

 

 

 

 

 

 

 

 

• Center wavelength: 850 nm

 

 

 

 

 

Rx input power

 

 

 

 

 

 

min: –17 dBm

 

 

 

 

 

 

max: –3 dBm

 

 

 

 

 

• Rated for 275 m (300 yards)

 

 

 

 

 

 

over 62.5-micron core cable

• Rated for 550 m (601 yards) over 50-micron core cable