Status LEDs
ERX Edge Routers
6-3
Figure 6-1 ERX-1400 series power switches
Initialization Sequence
Each ERX line module is initialized independently. As a result, the CLI
on the SRP module may become available before the line modules have
completed initialization. Commands relating to a line module may fail if
the module has not completed initialization. The show version
command can be used to display line module status. Do not enter
commands for a line module until its state is “online.”
Status LEDs
For information on the system’s LEDs, see Chapter8, Troubleshooting.
Powering Down
If you need to power down or remove the SRP module, first enter the
halt command to temporarily suspend the system’s operation. See ERX
System Basics Configuration Guide, Chapter 4, Managing the System for
more information.
Caution: If you do not use the halt command before removing or powering down
an SRP, the system’s NVS card may become corrupted.
If you shut down the system improperly, it will run an investigation of the
file allocation table (FAT) next time it reboots.
Power switches
Power input module