Status LEDs ERX Edge Routers
Power input module Power switches
Figure 6-1 ERX-1400 series power switches
Initialization Sequence
Each ERX line module is initialized independently. As a result, the CLI on the SRP module may become available before the line modules have completed initialization. Commands relating to a line module may fail if the module has not completed initialization. The show version command can be used to display line module status. Do not enter commands for a line module until its state is “online.”
Status LEDs
For information on the system’s LEDs, see Chapter 8, Troubleshooting.
Powering Down
If you need to power down or remove the SRP module, first enter the halt command to temporarily suspend the system’s operation. See ERX System Basics Configuration Guide, Chapter 4, Managing the System for more information.
Caution: If you do not use the halt command before removing or powering down an SRP, the system’s NVS card may become corrupted.
If you shut down the system improperly, it will run an investigation of the file allocation table (FAT) next time it reboots.