Understanding Status LEDs ERX Edge Routers

8-9

Table 8-4Troubleshooting abnormal LED activity on modules (continued)

Diagnostic Signs

Possible Problems

Actions

LINK LED is not lit

Ethernet connection is

1

Check that Ethernet cables are properly connected to

 

 

 

down.

 

both the Ethernet port and the appropriate network

 

 

 

 

 

device.

 

 

 

 

2

Contact Juniper Networks Customer Service.

RED ALM

System does not

1

Check that all cables are firmly plugged into OC3

 

 

 

recognize a port

 

ports and the attached network device.

 

 

 

connection.

2

Verify that cables are clean.

 

 

• Cabling is not connected

 

 

3

Test for faulty cables.

 

 

 

properly.

4

Verify clock source and configuration.

 

 

Cable is faulty.

 

 

5

Reset system.

 

 

Clocking problem exists.

 

 

 

 

Note: Problem is corrected when normal LED activity is

 

 

 

 

observed.

YEL ALM

Far end receive failure

1

Correct FERF problem.

Note: This LED is not

 

(FERF) exists.

2

Reset system.

 

 

functional on the HSSI line

 

 

 

 

module.

 

 

Note: Problem is corrected when normal LED activity

 

 

 

 

is observed.

• System will not boot.

A slot group is overloaded.

1

Issue the show version command to display board

Module(s) held offline.

 

 

 

status.

 

 

2

Review section on proper slot group configuration in

FAIL LED lights

 

 

 

 

 

 

 

Chapter 3, Installing ERX Modules.

 

 

 

 

3

Reconfigure system with correct slot group

 

 

 

 

 

configuration.

 

 

 

 

4

Reset system.

None

System temperature is

1

Check your console for a message indicating the

 

 

 

too high.

 

problem. If you have the “system” log set to a severity

 

 

Vents are blocked.

 

of WARNING or higher, a Warning message

 

 

 

indicating the failure is displayed.

 

 

• Fans are not operating.

 

 

 

2

Issue the show environment command to display

 

 

 

 

 

 

 

 

 

the temperatures. If the temperature is too high,

 

 

 

 

 

power down the system.

 

 

 

 

3

Regulate temperature.

 

 

 

 

4

Reset system.

 

 

 

 

 

 

Redundancy Status

You can determine the redundancy state of line modules by examining the online and redundant status LEDs. See Table 8-5.

Note: The REDUNDANT LED on the cOCx/STMx, FE-8, GE/FE, HSSI, OC3 (dual port), and OCx/STMx modules is nonfunctional.

Page 115
Image 115
Juniper Networks ERX-705, ERX-1410, ERX-1440, ERX-700 manual Redundancy Status