Understanding Status LEDs ERX Edge Routers
Table
Diagnostic Signs | Possible Problems | Actions | |||
LINK LED is not lit | • | Ethernet connection is | 1 | Check that Ethernet cables are properly connected to | |
|
|
| down. |
| both the Ethernet port and the appropriate network |
|
|
|
|
| device. |
|
|
|
| 2 | Contact Juniper Networks Customer Service. |
RED ALM | • | System does not | 1 | Check that all cables are firmly plugged into OC3 | |
|
|
| recognize a port |
| ports and the attached network device. |
|
|
| connection. | 2 | Verify that cables are clean. |
|
| • Cabling is not connected | |||
|
| 3 | Test for faulty cables. | ||
|
|
| properly. | 4 | Verify clock source and configuration. |
|
| • | Cable is faulty. | ||
|
| 5 | Reset system. | ||
|
| • | Clocking problem exists. | ||
|
|
|
| Note: Problem is corrected when normal LED activity is | |
|
|
|
| observed. | |
YEL ALM | • | Far end receive failure | 1 | Correct FERF problem. | |
Note: This LED is not |
| (FERF) exists. | 2 | Reset system. | |
|
| ||||
functional on the HSSI line |
|
|
|
| |
module. |
|
| Note: Problem is corrected when normal LED activity | ||
|
|
|
| is observed. | |
• System will not boot. | A slot group is overloaded. | 1 | Issue the show version command to display board | ||
• | Module(s) held offline. |
|
|
| status. |
|
| 2 | Review section on proper slot group configuration in | ||
• | FAIL LED lights |
|
| ||
|
|
|
|
| Chapter 3, Installing ERX Modules. |
|
|
|
| 3 | Reconfigure system with correct slot group |
|
|
|
|
| configuration. |
|
|
|
| 4 | Reset system. |
None | • | System temperature is | 1 | Check your console for a message indicating the | |
|
|
| too high. |
| problem. If you have the “system” log set to a severity |
|
| • | Vents are blocked. |
| of WARNING or higher, a Warning message |
|
|
| indicating the failure is displayed. | ||
|
| • Fans are not operating. |
| ||
|
| 2 | Issue the show environment command to display | ||
|
|
|
| ||
|
|
|
|
| the temperatures. If the temperature is too high, |
|
|
|
|
| power down the system. |
|
|
|
| 3 | Regulate temperature. |
|
|
|
| 4 | Reset system. |
|
|
|
|
|
|
Redundancy Status
You can determine the redundancy state of line modules by examining the online and redundant status LEDs. See Table
Note: The REDUNDANT LED on the cOCx/STMx,