Installing SRP I/O and SRP Modules
ERX Edge Routers
3-9
Caution: Always handle the module by its edges. Do not touch the components,
pins, leads, or solder connections.
5Remove the SRP module from its antistatic bag.
6Make sure that the ejectors are in position 1, as shown in Figure3-7.
Figure 3-7 Positioning the ejectors
7Position the module as follows:
For the ERX-1400 series, position the module vertically so that
the labeling is upright.
For the ERX-700 series, position the module horizontally so that
the labeling is to the right.
8Position the module in the chassis by placing it between the guides of
the selected slot, and slide the module until it stops.
The module stops sliding when the ejectors make contact with the
front of the chassis. Figure 3-8 shows how to install an SRP module
in the ERX-1400 series.
2
1
1
2