Installing SRP I/O and SRP Modules ERX Edge Routers

3-9

Caution: Always handle the module by its edges. Do not touch the components, pins, leads, or solder connections.

5Remove the SRP module from its antistatic bag.

6Make sure that the ejectors are in position 1, as shown in Figure 3-7.

2

1

1

2

Figure 3-7Positioning the ejectors

7Position the module as follows:

For the ERX-1400 series, position the module vertically so that the labeling is upright.

For the ERX-700 series, position the module horizontally so that the labeling is to the right.

8Position the module in the chassis by placing it between the guides of the selected slot, and slide the module until it stops.

The module stops sliding when the ejectors make contact with the front of the chassis. Figure 3-8shows how to install an SRP module in the ERX-1400 series.

Page 55
Image 55
Juniper Networks ERX-705, ERX-1410, ERX-1440, ERX-700 manual 7Positioning the ejectors