Cabling I/O Modules
ERX Edge Routers
4-13
Cabling LC Duplex Connectors
In accordance with EN60825-1, Safety of Laser Products - Part 1:
Equipment Class, Requirements, and User’s Guide (2001), multimode
I/O modules with LC connectors are defined as follows:
CLASS 1 LED PRODUCT.
In accordance with EN60825-1, Safety of Laser Products - Part 1:
Equipment Class, Requirements, and User’s Guide (2001), single-mode
I/O modules with LC connectors are defined as follows:
CLASS 1 LASER PRODUCT.
To cable I/O modules with LC duplex connectors:
Warning: Do not look directly into LC-style fiber connectors. The fiber-optic laser
used in single-mode fiber (SMF) meets the regulatory requirements for casual
exposure to the eye; however, looking directly into a laser can cause eye damage.
Warning: IEC 825, Class 1 laser fiber connectors are for connection only to Class
1 laser devices.
1Insert the TX male fiber connector into the selected port.
2Terminate the other end in the appropriate network connection.
3Repeat steps 1 and 2 for the RX fiber connector.
4Repeat steps 1–3 for the remaining ports.