Johnson Controls TG9S'MP Section Viii Combustion Air And Vent System, UIM-H-0712, Model Input

Page 22
SECTION VIII: COMBUSTION AIR AND VENT SYSTEM

364861-UIM-H-0712

SECTION VIII: COMBUSTION AIR AND VENT SYSTEM

COMBUSTION AIR AND VENT SAFETY

This Category IV, dual certified direct vent furnace is designed for resi- dential application. It may be installed without modification to the con- densate system in a basement, garage, equipment room, alcove, attic or any other indoor location where all required clearance to combusti- bles and other restrictions are met. The combustion air and the venting system must be installed in accordance with Section 5.3, Air for Com- bustion and Ventilation, of the National Fuel Gas Code Z223.1/NFPA 54 (latest edition), or Sections 7.2, 7.3 or 7.4 of CSA B149.1, National Gas and Propane Codes (latest edition) or applicable provisions of the local building code and these instructions.

The “VENT SYSTEM” must be installed as specified in these instruc- tions for Residential and non-HUD Modular Homes. The direct vent system is the only configuration that can be installed in a non-HUD Modular Home.

This furnace may not be common vented with any other appliance, since it requires separate, properly sized air intake and vent lines. The furnace shall not be connected to any type of B, BW or L vent or vent connector, and not connected to any portion of a factory-built or masonry chimney

The furnace shall not be connected to a chimney flue serving a sepa- rate appliance designed to burn solid fuel.

When combustion air pipe is installed above a suspended ceiling or when it passes through a warm and humid space, the pipe must be insulated with 1/2” Armaflex or other heat resistant type insulation if two feet or more of pipe is exposed.

Vent piping must be insulated if it will be subjected to freezing temper- atures such as routing through unheated areas or through an unused chimney.

COMBUSTION AIR/VENT PIPE SIZING

The size of pipe required will be determined by the furnace model, the total length of pipe required and the number of elbows required.

Table 7 lists the maximum equivalent length of pipe allowed for each model of furnace. The equivalent length of elbows is shown in Table 9. The equivalent length of the vent system is the total length of straight pipe PLUS the equivalent length of all of the elbows.

The following rules must also be followed:

1.Long radius (sweep) elbows are recommended. Standard elbows may be used, but since they have a longer equivalent length, they will reduce the total length of pipe that will be allowed. Short radius (plumbing vent) elbows are not allowed. The standard dimensions of the acceptable elbows are shown below.

2.The maximum equivalent length listed in Table 7 is for the vent pip- ing and the air intake piping separately. For example, if the table allows 65 equivalent feet for a particular model, then the vent can have 65 equivalent feet of pipe, AND the combustion air intake can have another 65 equivalent feet of pipe.

3.Three vent terminal elbows (two for the vent and one for the com- bustion air intake) are already accounted for and need not be included in the equivalent length calculation.

4.All combustion air and vent pipe must conform to American National Standards Institute (ANSI) and American Society for Test- ing and Materials (ASTM) standards D1785 (Schedule 40 PVC), D2665 (PVC-DWV), F891 (PVC-DWV Cellular Core), D2261 (ABS- DWV) or F628 (Schedule 40 ABS). Pipe cement and primer must conform to ASTM Standard D2546 (PVC) or D2235 (ABS). If ABS pipe is to be used, any joint where ABS pipe is joined to PVC pipe must be glued with cement that is approved for use with BOTH materials. Metallic materials must not be used for venting or air intake.

5.If a flexible connector is used in the vent system, it must be made of a material that is resistant to acidic exposure and to at least 225°F (107°C) temperature. Flexible connectors are also allowed in the combustion air pipe.

6.All models are supplied with 2" (5.1 cm) vent connections. When the pipe must be increased to 3" (7.6 cm) diameter, the transition from 2" to 3" must be done as close to the furnace as possible. For upflow models, the transition from 2" to 3" should be done immedi- ately above the furnace. For downflow or horizontal models, the transition from 2" to 3" pipe should be done immediately after exit- ing the furnace.

7.In Canada, vents shall be certified to ULC S636, Standard for Type BH Gas Venting Systems.

8.In Canada, the first three feet (91.4 cm) of the vent must be readily accessible for inspection.

9.For single pipe systems it is recommended to install the combustion air coupling provided and install approximately 18” (46 cm) of PVC pipe on the furnace.

10.Minimum vent length for all models is 5 feet (1.5 m).

TABLE 7: Maximum Equivalent Pipe Length

Model Input
Pipe Size
Maximum

Equivalent

BTUH (kW)

Inches (cm)

length feet (m)

 

 

 

 

 

40,000

2 (5.1)

65 (19.8)

 

 

 

40,000

3 (7.6)

90 (27.4)

 

 

 

 

40,000

4 (10.2)

150

(45.7)

 

 

 

60,000

2 (5.1)

65 (19.8)

 

 

 

60,000

3 (7.6)

90 (27.4)

 

 

 

 

60,000

4 (10.2)

150

(45.7)

 

 

 

80,000

2 (5.1)

65 (19.8)

 

 

 

80,000

3 (7.6)

90 (27.4)

 

 

 

 

80,000

4 (10.2)

150

(45.7)

 

 

 

 

100,000

2 (5.1)

30

(9.1)

 

 

 

100,000

3 (7.6)

90 (27.4)

 

 

 

 

100,000

4 (10.2)

150

(45.7)

 

 

 

 

120,000

2 (5.1)

30

(9.1)

 

 

 

120,000

3 (7.6)

90 (27.4)

 

 

 

 

120,000

4 (10.2)

150

(45.7)

 

 

 

130,000

3 (7.6)

85 (25.9)

 

 

 

 

130,000

4 (10.2)

150

(45.7)

 

 

 

 

22

Johnson Controls Unitary Products

Image 22
Contents MODELS TG9S*MP, GG9S*MP INSTALLATION MANUALRESIDENTIAL GAS FURNACE 95.5% AFUE Single Stage Multi-positionSAFETY REQUIREMENTS SECTION I SAFETYSPECIFIC SAFETY RULES AND PRECAUTIONS 364861-UIM-H-0712STEP 6 - Gas Piping and Gas Pipe Pressure Testing STEP 1 - SafetySTEP 2 - General Installation 364861-UIM-H-0712364861-UIM-H-0712 Clearances for access/serviceInstallation in a residential garage INSPECTIONinstalled FLOOR BASE AND DUCTWORK INSTALLATION - DOWNFLOWThe duct system’s design and installation must SECTION II DUCTWORKFURNACE ASSEMBLY - MC & FC SERIES COILS COIL INSTALLATIONCOIL/FURNACE ASSEMBLY - MC/FC/PC SERIES COILS COIL FLANGE INSTALLATIONBOTTOM RETURN AND ATTIC INSTALLATIONS DOWNFLOW DUCT CONNECTORSCOIL / FURNACE ASSEMBLY - HC SERIES COILS DIMENSION “C” INCH364861-UIM-H-0712 ATTIC INSTALLATIONSUSPENDED FURNACE / CRAWL SPACE INSTALLATION DOWNFLOW APPLICATIONCabinet Dimensions Inches FILTER INSTALLATIONFIGURE 13 Dimensions attempt to install filters inside the furnaceGAS PIPING INSTALLATION DANGERGAS SAFETY SECTION IV GAS PIPINGELECTRICAL POWER CONNECTIONS SECTION V ELECTRICAL POWERHIGH ALTITUDE PRESSURE SWITCH CONVERSION DANGERSUPPLY VOLTAGE CONNECTIONS LOW VOLTAGE CONTROL WIRING CONNECTIONS364861-UIM-H-0712 Input364861-UIM-H-0712 AC 5DJohnson Controls Unitary Products Single Stage Heat Pump - Single Stage PSC Furnace HP 2C364861-UIM-H-0712 SECTION VI TWINNING AND STAGING ACCESSORY CONNECTIONSELECTRONIC AIR CLEANER CONNECTION 364861-UIM-H-0712Staging Operation 364861-UIM-H-0712Twinning Operation STAGINGJohnson Controls Unitary Products 364861-UIM-H-0712CONDENSATE DRAIN TERMINATION Open Stand Pipe Anti-siphonair vent 5” Min TeeINDUCER ROTATED FOR RIGHT SIDE VENTING pressure switch hose1 pressure switchhose UPFLOWDOWNFLOW - INDUCER ROTATED FOR LEFT SIDE VENTING AIRFLOW AIRFLOWDOWNFLOW - INDUCER ROTATED FOR RIGHT SIDE VENTING INDUCER AS RECEIVED Except for 130K Model HORIZONTAL - LEFT INDUCER ROTATEDHORIZONTAL - LEFT AIRFLOWHORIZONTAL - RIGHT INDUCER ROTATED Move pressure switch hose to this position1Move pressure switch hose to this position HORIZONTAL - RIGHT364861-UIM-H-0712 COMBUSTION AIR AND VENT SAFETYSECTION VIII COMBUSTION AIR AND VENT SYSTEM COMBUSTION AIR/VENT PIPE SIZINGElbow A Dimension COMBUSTION AIR AND VENT PIPING ASSEMBLYFIGURE 29 Dimensions 364861-UIM-H-0712364861-UIM-H-0712 Canadian Installations1,3US Installation2,3 VENT CLEARANCESVENT APPLICATIONS AND TERMINATION 364861-UIM-H-0712VENT SYSTEM VENTING MULTIPLE UNITSCOMBUSTION AIR SUPPLY 364861-UIM-H-0712DOWNWARD VENTING Outdoor Combustion AirDampers, Louvers and Grilles Canada Only 364861-UIM-H-0712Ambient Combustion Air Supply Combustion Air Source From OutdoorsVentilated Combustion Air 364861-UIM-H-0712Air Supply Openings and Ducts Ventilated Combustion Air Termination364861-UIM-H-0712 SECTION IX START-UPAND ADJUSTMENTSSpecially Engineered Installations VENT BLOWER ROTATIONCALCULATING THE FURNACE INPUT NAT. GAS 364861-UIM-H-0712IGNITION SYSTEM SEQUENCE HOT SURFACE IGNITION SYSTEM1 Revolution 364861-UIM-H-0712Johnson Controls Unitary Products 1 Cu FtRead the inlet gas pressure ADJUSTMENT OF MANIFOLD GAS PRESSURE & INPUT RATE364861-UIM-H-0712 Read the manifold gas pressureDANGER ADJUSTMENT OF TEMPERATURE RISEADJUSTMENT OF FAN CONTROL SETTINGS 364861-UIM-H-0712364861-UIM-H-0712 Bottom Airflow Data SCFM364861-UIM-H-0712 Johnson Controls Unitary ProductsBLOWER DOOR SAFETY SWITCH SECTION X SAFETY CONTROLSSECTION XI NORMAL OPERATION AND DIAGNOSTICS ROLLOUT SWITCH CONTROLS364861-UIM-H-0712 FURNACE CONTROL DIAGNOSTICSJohnson Controls Unitary Products DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL SECTION XII REPLACEMENT PARTS LISTREPLACEMENT PART CONTACT INFORMATION 364861-UIM-H-0712DIAGRAM Wiring Diagram - 95% Single-StageFurnaceSECTION XIII WIRING Johnson Controls Unitary ProductsYork International Corp 5005 York Drive Norman, OK