Johnson Controls TG9S'MP Section Xii Replacement Parts List, Replacement Part Contact Information

Page 38
DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL

364861-UIM-H-0712

DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL

The control in this furnace is equipped with memory that will store up to five error codes to allow a service technician to diagnose problems more easily. This memory will be retained even if power to the furnace is lost. This feature should only be used by a qualified service tech- nician.

If more than five error codes have occurred since the last reset, only the five most recent will be retained. The furnace control board has a but- ton, labeled "LAST ERROR" that is used to retrieve error codes. This function will only work if there are no active thermostat signals. So any call for heating, cooling or continuous fan must be terminated before attempting to retrieve error codes.

SECTION XII: REPLACEMENT PARTS LIST

DESCRIPTION

MOTOR

MOTOR, DIRECT DRIVE BLOWER

BLOWER, COMBUSTION

ELECTRICAL

CAPACITOR, RUN

SWITCH, LIMIT

CONTROL, FURNACE

IGNITER

SENSOR, FLAME

SWITCHES, PRESSURE

SWITCH, DOOR

TRANSFORMER

VALVE, GAS

CONTROL, TEMPERATURE

AIR MOVING

HOUSING, BLOWER

WHEEL, BLOWER

FABRICATED PARTS

RESTRICTOR, COMBUSTION BLOWER

BURNER, MAIN GAS

BRACKET, IGNITER

SHELF, BLOWER

RAIL, BLOWER (2 Req’d)

BRACKET, BLOWER TRACK (2 Req’d)

HEAT EXCHANGER ASS’Y

To retrieve the error codes, push the LAST ERROR button. The LED on the control will then flash the error codes that are in memory, starting with the most recent. There will be a two-second pause between each flash code. After the error codes have all been displayed, the LED will resume the normal slow green flash after a five second pause. To repeat the series of error codes, push the button again.

If there are no error codes in memory, the LED will flash two green flashes. To clear the memory, push the LAST ERROR button and hold it for more than five seconds. The LED will flash three green flashes when the memory has been cleared, then will resume the normal slow green flash after a five-second pause.

DESCRIPTION

FABRICATED PARTS Continued

MANIFOLD, GAS

PAN, BOTTOM

PANEL, TOP

PANEL, DOOR (2 Req’d)

PANEL, BLOCKOFF

MISCELLANEOUS

ORIFICE, BURNER (Natural #45)

SIGHT GLASS, OVAL (2 Req’d)

GASKET, FOAM (Door) (1.5 ft req’d)

PAN, CONDENSATE

BRACKET, DOOR

HARNESS, WIRING

FERRULE (3 Req’d)

GROMMET (3 Req’d)

MOTOR MOUNT

TUBING, SILICON

HOSE, RAIN GUTTER

HOSE, CONDENSATE

PLUG, SEAL, 7/8”

PLUG, SEAL, 2-3/8”

PLUG, VENT PIPE

BAG, PARTS

KNOB, QUARTER TURN (4 Req’d)

DIAGRAM, WIRING

REPLACEMENT PART CONTACT INFORMATION

This is a generic parts list. To request a complete parts list, refer to the contact information below:

Visit our website at www.source1parts.com for the following information:

1.Search for a part or browse the catalog.

2.Find a dealer or distributor.

3.Customer Service contact information.

a.Click on the “Brand Links” button

b.Click on the “Customer Service” buttont

You can contact us by mail. Just send a written request to:

Johnson Controls Unitary Products

Consumer Relations

5005 York Drive

Norman, OK 73069

38

Johnson Controls Unitary Products

Image 38
Contents MODELS TG9S*MP, GG9S*MP INSTALLATION MANUALRESIDENTIAL GAS FURNACE 95.5% AFUE Single Stage Multi-positionSAFETY REQUIREMENTS SECTION I SAFETYSPECIFIC SAFETY RULES AND PRECAUTIONS 364861-UIM-H-0712STEP 6 - Gas Piping and Gas Pipe Pressure Testing STEP 1 - SafetySTEP 2 - General Installation 364861-UIM-H-0712364861-UIM-H-0712 Clearances for access/serviceInstallation in a residential garage INSPECTIONinstalled FLOOR BASE AND DUCTWORK INSTALLATION - DOWNFLOWThe duct system’s design and installation must SECTION II DUCTWORKFURNACE ASSEMBLY - MC & FC SERIES COILS COIL INSTALLATIONCOIL/FURNACE ASSEMBLY - MC/FC/PC SERIES COILS COIL FLANGE INSTALLATIONBOTTOM RETURN AND ATTIC INSTALLATIONS DOWNFLOW DUCT CONNECTORSCOIL / FURNACE ASSEMBLY - HC SERIES COILS DIMENSION “C” INCH364861-UIM-H-0712 ATTIC INSTALLATIONSUSPENDED FURNACE / CRAWL SPACE INSTALLATION DOWNFLOW APPLICATIONCabinet Dimensions Inches FILTER INSTALLATIONFIGURE 13 Dimensions attempt to install filters inside the furnaceGAS PIPING INSTALLATION DANGERGAS SAFETY SECTION IV GAS PIPINGELECTRICAL POWER CONNECTIONS SECTION V ELECTRICAL POWERHIGH ALTITUDE PRESSURE SWITCH CONVERSION DANGERSUPPLY VOLTAGE CONNECTIONS LOW VOLTAGE CONTROL WIRING CONNECTIONS364861-UIM-H-0712 InputJohnson Controls Unitary Products AC 5D364861-UIM-H-0712 364861-UIM-H-0712 HP 2CSingle Stage Heat Pump - Single Stage PSC Furnace SECTION VI TWINNING AND STAGING ACCESSORY CONNECTIONSELECTRONIC AIR CLEANER CONNECTION 364861-UIM-H-0712Staging Operation 364861-UIM-H-0712Twinning Operation STAGINGJohnson Controls Unitary Products 364861-UIM-H-0712CONDENSATE DRAIN TERMINATION Open Stand Pipe Anti-siphonair vent 5” Min TeeINDUCER ROTATED FOR RIGHT SIDE VENTING pressure switch hose1 pressure switchhose UPFLOWDOWNFLOW - INDUCER ROTATED FOR RIGHT SIDE VENTING AIRFLOW AIRFLOWDOWNFLOW - INDUCER ROTATED FOR LEFT SIDE VENTING INDUCER AS RECEIVED Except for 130K Model HORIZONTAL - LEFT INDUCER ROTATEDHORIZONTAL - LEFT AIRFLOWHORIZONTAL - RIGHT INDUCER ROTATED Move pressure switch hose to this position1Move pressure switch hose to this position HORIZONTAL - RIGHT364861-UIM-H-0712 COMBUSTION AIR AND VENT SAFETYSECTION VIII COMBUSTION AIR AND VENT SYSTEM COMBUSTION AIR/VENT PIPE SIZINGElbow A Dimension COMBUSTION AIR AND VENT PIPING ASSEMBLYFIGURE 29 Dimensions 364861-UIM-H-0712364861-UIM-H-0712 Canadian Installations1,3US Installation2,3 VENT CLEARANCESVENT APPLICATIONS AND TERMINATION 364861-UIM-H-0712VENT SYSTEM VENTING MULTIPLE UNITSCOMBUSTION AIR SUPPLY 364861-UIM-H-0712DOWNWARD VENTING Outdoor Combustion AirDampers, Louvers and Grilles Canada Only 364861-UIM-H-0712Ambient Combustion Air Supply Combustion Air Source From OutdoorsVentilated Combustion Air 364861-UIM-H-0712Air Supply Openings and Ducts Ventilated Combustion Air Termination364861-UIM-H-0712 SECTION IX START-UPAND ADJUSTMENTSSpecially Engineered Installations VENT BLOWER ROTATIONCALCULATING THE FURNACE INPUT NAT. GAS 364861-UIM-H-0712IGNITION SYSTEM SEQUENCE HOT SURFACE IGNITION SYSTEM1 Revolution 364861-UIM-H-0712Johnson Controls Unitary Products 1 Cu FtRead the inlet gas pressure ADJUSTMENT OF MANIFOLD GAS PRESSURE & INPUT RATE364861-UIM-H-0712 Read the manifold gas pressureDANGER ADJUSTMENT OF TEMPERATURE RISEADJUSTMENT OF FAN CONTROL SETTINGS 364861-UIM-H-0712364861-UIM-H-0712 Bottom Airflow Data SCFM364861-UIM-H-0712 Johnson Controls Unitary ProductsBLOWER DOOR SAFETY SWITCH SECTION X SAFETY CONTROLSSECTION XI NORMAL OPERATION AND DIAGNOSTICS ROLLOUT SWITCH CONTROLSJohnson Controls Unitary Products FURNACE CONTROL DIAGNOSTICS364861-UIM-H-0712 DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL SECTION XII REPLACEMENT PARTS LISTREPLACEMENT PART CONTACT INFORMATION 364861-UIM-H-0712DIAGRAM Wiring Diagram - 95% Single-StageFurnaceSECTION XIII WIRING Johnson Controls Unitary ProductsYork International Corp 5005 York Drive Norman, OK