Johnson Controls GG9S'MP installation manual Installation Manual, Residential Gas Furnace

Page 1
INSTALLATION MANUAL

INSTALLATION MANUAL

RESIDENTIAL GAS FURNACE

MODELS: TG9S*MP, GG9S*MP

(95.5% AFUE Single Stage Multi-position)

LIST OF SECTIONS

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 TWINNING AND STAGING . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

CONDENSATE PIPING AND FURNACE

VENTING CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . 16

COMBUSTION AIR and VENT SYSTEM . . . . . . . . . . . . . . . . . 22 START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . 29 SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 NORMAL OPERATION AND DIAGNOSTICS . . . . . . . . . . . . . 36 REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . 38 REPLACEMENT PART CONTACT INFORMATION . . . . . . . . 38 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

LIST OF FIGURES

Duct Attachment

. 5

Vertical Applications

. 6

Coil Flange

. 6

Horizontal Right Application

. 6

Horizontal Left Application

. 6

PC Series Upflow Coil Installation

. 7

Horizontal Left or Right application (Right Shown)

. 7

Combustible Floor Base Accessory

. 7

Horizontal Application

. 7

Typical Attic Installation

. 8

Typical Suspended Furnace / Crawl Space Installation

. 8

Downflow Venting

. 8

Dimensions

. 9

Side Return Cutout Markings

10

Gas Valve

10

Gas Piping

10

Electrical Wiring

12

Thermostat Chart - Single Stage AC

 

with Single Stage PSC Furnaces

13

Thermostat Chart - Single Stage HP

 

with Single Stage PSC Furnaces

14

Typical Twinned Furnace Application

15

Twinning Wiring Diagram

16

Staging Wiring Diagram

16

Typical. Condensate drain, vertical installation . . . . . . . . . . . . . 17 Typical. Combustion Pipe Drain Tee . . . . . . . . . . . . . . . . . . . . . 17 Upflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Downflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Horizontal Left Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Horizontal Right Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 21 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Termination Configuration - 1 Pipe . . . . . . . . . . . . . . . . . . . . . . 25 Termination Configuration - 2 Pipe . . . . . . . . . . . . . . . . . . . . . . 25 Termination Configuration - 2 Pipe Basement . . . . . . . . . . . . . 25

Double Horizontal Combustion

Air Intake and Vent Termination . . . . . . . . . . . . . . . . . . . . . . . . 26

Double Vertical Combustion

Air Intake and Vent Termination . . . . . . . . . . . . . . . . . . . . . . . . 26 Downward Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Direct Vent Air Intake Connection and Vent Connection . . . . . . 26 Combustion Airflow Path Through The Furnace Casing . . . . . . 27 Outside and Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . 28 Attic and Crawl Space Combustion Air Termination . . . . . . . . . 28 Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

LIST OF TABLES

Unit Clearances to Combustibles

. 4

Estimated Free Area

27

Coil Projection Dimensions - PC Series Coils

. 7

Unconfined Space Minimum Area

27

Cabinet and Duct Dimensions

. 9

Free Area

27

Recommended Filter Sizes (High Velocity 600 FPM)

. 9

Gas Rate (CU FT/HR) at Full Input

31

Nominal Manifold Pressure - High Fire

11

Inlet Gas Pressure Range

32

Ratings & Physical / Electrical Data

12

Nominal Manifold Pressure

32

Maximum Equivalent Pipe Length

22

Blower Performance CFM - Any Position

 

Elbow Dimensions

23

(without filter) - Bottom Return

34

Equivalent Length of Fittings

23

Blower Performance CFM - Any Position

35

Combustion Air Intake and Vent Connection

 

(without filter) - Left Side Return

 

 

 

Size at Furnace (All Models)

23

 

 

364861-UIM-H-0712
Image 1
Contents RESIDENTIAL GAS FURNACE INSTALLATION MANUALMODELS TG9S*MP, GG9S*MP 95.5% AFUE Single Stage Multi-positionSPECIFIC SAFETY RULES AND PRECAUTIONS SECTION I SAFETYSAFETY REQUIREMENTS 364861-UIM-H-0712STEP 2 - General Installation STEP 1 - SafetySTEP 6 - Gas Piping and Gas Pipe Pressure Testing 364861-UIM-H-0712Installation in a residential garage Clearances for access/service364861-UIM-H-0712 INSPECTIONThe duct system’s design and installation must FLOOR BASE AND DUCTWORK INSTALLATION - DOWNFLOWinstalled SECTION II DUCTWORKCOIL/FURNACE ASSEMBLY - MC/FC/PC SERIES COILS COIL INSTALLATIONFURNACE ASSEMBLY - MC & FC SERIES COILS COIL FLANGE INSTALLATIONCOIL / FURNACE ASSEMBLY - HC SERIES COILS DOWNFLOW DUCT CONNECTORSBOTTOM RETURN AND ATTIC INSTALLATIONS DIMENSION “C” INCHSUSPENDED FURNACE / CRAWL SPACE INSTALLATION ATTIC INSTALLATION364861-UIM-H-0712 DOWNFLOW APPLICATIONFIGURE 13 Dimensions FILTER INSTALLATIONCabinet Dimensions Inches attempt to install filters inside the furnaceGAS SAFETY DANGERGAS PIPING INSTALLATION SECTION IV GAS PIPINGHIGH ALTITUDE PRESSURE SWITCH CONVERSION SECTION V ELECTRICAL POWERELECTRICAL POWER CONNECTIONS DANGER364861-UIM-H-0712 LOW VOLTAGE CONTROL WIRING CONNECTIONSSUPPLY VOLTAGE CONNECTIONS Input364861-UIM-H-0712 AC 5DJohnson Controls Unitary Products Single Stage Heat Pump - Single Stage PSC Furnace HP 2C364861-UIM-H-0712 ELECTRONIC AIR CLEANER CONNECTION ACCESSORY CONNECTIONSSECTION VI TWINNING AND STAGING 364861-UIM-H-0712Twinning Operation 364861-UIM-H-0712Staging Operation STAGINGCONDENSATE DRAIN TERMINATION 364861-UIM-H-0712Johnson Controls Unitary Products Open Stand Pipe Anti-siphonair vent 5” Min Tee1 pressure switchhose pressure switch hoseINDUCER ROTATED FOR RIGHT SIDE VENTING UPFLOWDOWNFLOW - INDUCER ROTATED FOR LEFT SIDE VENTING AIRFLOW AIRFLOWDOWNFLOW - INDUCER ROTATED FOR RIGHT SIDE VENTING HORIZONTAL - LEFT HORIZONTAL - LEFT INDUCER ROTATEDINDUCER AS RECEIVED Except for 130K Model AIRFLOW1Move pressure switch hose to this position Move pressure switch hose to this positionHORIZONTAL - RIGHT INDUCER ROTATED HORIZONTAL - RIGHTSECTION VIII COMBUSTION AIR AND VENT SYSTEM COMBUSTION AIR AND VENT SAFETY364861-UIM-H-0712 COMBUSTION AIR/VENT PIPE SIZINGFIGURE 29 Dimensions COMBUSTION AIR AND VENT PIPING ASSEMBLYElbow A Dimension 364861-UIM-H-0712US Installation2,3 Canadian Installations1,3364861-UIM-H-0712 VENT CLEARANCESVENT SYSTEM 364861-UIM-H-0712VENT APPLICATIONS AND TERMINATION VENTING MULTIPLE UNITSDOWNWARD VENTING 364861-UIM-H-0712COMBUSTION AIR SUPPLY Outdoor Combustion AirAmbient Combustion Air Supply 364861-UIM-H-0712Dampers, Louvers and Grilles Canada Only Combustion Air Source From OutdoorsAir Supply Openings and Ducts 364861-UIM-H-0712Ventilated Combustion Air Ventilated Combustion Air TerminationSpecially Engineered Installations SECTION IX START-UPAND ADJUSTMENTS364861-UIM-H-0712 VENT BLOWER ROTATIONIGNITION SYSTEM SEQUENCE 364861-UIM-H-0712CALCULATING THE FURNACE INPUT NAT. GAS HOT SURFACE IGNITION SYSTEMJohnson Controls Unitary Products 364861-UIM-H-07121 Revolution 1 Cu Ft364861-UIM-H-0712 ADJUSTMENT OF MANIFOLD GAS PRESSURE & INPUT RATERead the inlet gas pressure Read the manifold gas pressureADJUSTMENT OF FAN CONTROL SETTINGS ADJUSTMENT OF TEMPERATURE RISEDANGER 364861-UIM-H-0712Bottom Airflow Data SCFM 364861-UIM-H-0712Johnson Controls Unitary Products 364861-UIM-H-0712SECTION XI NORMAL OPERATION AND DIAGNOSTICS SECTION X SAFETY CONTROLSBLOWER DOOR SAFETY SWITCH ROLLOUT SWITCH CONTROLS364861-UIM-H-0712 FURNACE CONTROL DIAGNOSTICSJohnson Controls Unitary Products REPLACEMENT PART CONTACT INFORMATION SECTION XII REPLACEMENT PARTS LISTDIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL 364861-UIM-H-0712SECTION XIII WIRING Wiring Diagram - 95% Single-StageFurnaceDIAGRAM Johnson Controls Unitary ProductsNorman, OK York International Corp 5005 York Drive