FireplaceXtrordinair 44 DV XXL EF manual Vertical Terminations with Two Vertical 90 Elbows

Page 20

2 0

Installation (for qualified installers only)

Vertical Terminations with Two Vertical 90° Elbows

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.

0feet

 

5feet

10feet

15feet

20'(max)

40' (max)

 

 

 

 

 

 

 

 

 

 

40' (max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restrictor

 

 

 

 

 

 

 

 

 

 

Position # 6

 

 

 

 

 

35 feet

 

 

 

 

 

 

 

 

 

35 feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

Restrictor positions

 

 

 

 

 

 

 

 

 

 

are based upon

 

 

 

 

30 feet

 

 

 

 

 

lab tests. The

 

 

 

30 feet

 

 

 

 

 

ideal restrictor

 

 

 

 

 

 

 

 

 

 

 

position may vary

 

 

 

 

 

 

 

 

 

 

 

 

slightly, especially

 

 

 

 

 

 

 

 

 

 

 

 

when the

 

 

 

 

 

 

 

 

 

 

 

 

termination is near

 

 

 

 

25 feet

 

 

 

 

a demarkation line.

 

 

25 feet

 

 

 

 

 

 

 

 

20 feet

 

20 feet

 

 

 

15 feet

Restrictor

15 feet

Position # 5

 

 

 

10 feet

 

 

 

10 feet

(min.)

 

 

 

(min.)

5 feet

 

NOTE:

 

5 feet

 

Horizontal sections require a

 

 

 

 

 

1/4" rise every 12" of travel.

 

0 feet

 

 

 

0 feet

0feet

5feet

10feet

15feet

20'(max)

 

 

 

 

This is considered a

NOTE:

 

H2

 

vertical elbow

 

 

 

 

• One horizontal elbow is allowed.

 

 

Horizontal length is calculated by

It may be a 45° or 90° elbow.

 

 

 

 

adding both lengths of horizontal run

 

 

 

 

 

 

(Horizontal Length = H1 + H2).

This is considered a horizontal elbow because it

H1

 

 

is between two horizontal sections.

 

 

This is considered a

 

 

 

 

 

 

 

 

 

 

 

vertical elbow

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Image 20
Contents DV XXL EF Manual Introduction IntroductionImportant Information Travis Industries 4050114 0 0 1 1 4Safety Precautions If YOU Smell GAS 4050114 0 0 1 1 4 Travis IndustriesThis Manual Heating Specifications Natural Gas Propane Features and SpecificationsFeatures Installation Options Additional Items Required Installation WarningsPacking List Installation Overview Recommended Installation ProcedureFireplace Placement Requirements Minimum Framing DimensionsClearances Vertical StandoffCorner Installations Raised FireplacesGas Line Requirements FuelGas Line Connection Gas Inlet PressureElectrical Connection Fireplace junction boxVent Requirements Altitude ConsiderationsPart Numbers for 8 Diameter Vent Horizontal RunsVent Installation Vertical Vent RequirementsApproved Vent Configurations Restrictor PositionElbows Measuring Vent Lengths Vertical Terminations with 0, 2, or 4 45 Offsets Zero or Two 45 Offsets Four 45 OffsetsHorizontal Terminations with One Vertical Elbow Horizontal Terminations with Three Vertical Elbows Vertical Terminations with Two Vertical 90 Elbows Termination Requirements see the illustration below Hearth Requirements Floor Mounted FireplacesFacing Requirements Minimum Top Facing ClearanceFace Dimensions Modifying the Face Angle for Rectangular FacesFireplace Facing Detail Facing Example Facing Under 1 Thick FireplaceFacing Example Facing Over 1 Thick Arched FacesMinimum Mantel Clearance Mantel RequirementsCombustible or Non-Combustible Mantels Re-Attaching the Glass Frame Arch Covers both sidesGlass Frame Removal and Installation Place the Rear Log Place the Middle Logs Placing the Front Log Placing the Twigs Correct Arch Faces Architectural Faces Operation3 Before You Begin Location of Controls See explanation below8Operation Starting The Pilot FlameTurning the Fireplace On and Off Adjusting the Flame HeightStarting the Fireplace for the First Time Adjusting the Blower Speed Optional Power Heat Duct0Operation Normal Operating SoundsYearly Service Procedure Maintaining Your Fireplaces AppearanceMaintenance Troubleshooting TableWhat Prevents Gas Buildup How this Fireplace WorksWhat Turns the Main Burners On and Off Wiring Diagram Replacement Parts ListSafety Label Fireplace Xtrordinair 44DVXXL6Limited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyBurner Replacement LP Conversion InstructionsOptional Equipment for qualified installers only Orifice Identification Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Modulating Remote Installation Maintenance Instructions6Index