| 6 | Features and Specifications | |||
|
|
|
|
| |
| Features: | Installation Options: |
|
| |
| - Works During Power Outages (millivolt system) | - Residential or Mobile Home |
| ||
| - | High Efficiency | - Straight or Corner Placement |
| |
| - Optional Thermostat or Remote Control | - Flush or Recessed Face |
| ||
| - Realistic "Wood Fire" Look |
| |||
| - Raised or Floor Hearth |
|
| ||
| - Two Quiet Blowers for Effective Heat Distribution |
|
| ||
| - Internal or External Chase |
| |||
| - | Convenient Operating Controls |
| ||
| - Horizontal or Vertical Vent |
| |||
| - |
| |||
| - Power Heat Duct |
|
| ||
| - | Low Maintenance |
|
| |
|
|
|
| ||
| Heating Specifications: | Natural Gas | Propane | ||
| Approximate Heating Capacity (in square feet)* | Up to 3,000 | Up to 3,000 | ||
| BTU Input Per Hour (from high to low) | 58, 000 – 43,000 | 58, 000 – 44,000 | ||
| BTU Output on High (with blowers on) | 42,920 | 44,080 |
| |
| Efficiency** (with blowers on) | 74 % | 76 % |
| |
| AFUE (Annual Fuel Utilization Efficiency) | 68 % | 69 % |
| |
*Heating capacity will vary with floor plan, insulation, use of Power Heat Duct, and outside temperature.
**Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system.
Dimensions:
| Vent has an external diameter of 8" | |
Weight: 325 Lbs. |
| |
| ||
The electrical connection is made in the lower right rear corner.
Power Heat
Vent
1"
WARNING:
A 1" clearance from the
fireplace enclosure is
required along the sides
and back of the fireplace.
Nail Down Plate (used to secure the fireplace to the floor) ![]()
Thermostat Wire Hole (on both sides)
1"
40"
1"
*Includes the required 1" clearance.
Gas Inlet (on both sides)
6 | 4050114 | 1 0 0 - 0 1 1 4 9 |