Optional Equipment (for qualified installers only) 5 3

5 Attach the grill (and wall adapter, if necessary).

Screws (included with this kit)

 

 

Wall Adapter

 

 

(for use when the blower box

Phillips

Grill

protrudes from the wall -

primarily on 2 x 4

Screwdriver

 

 

 

WIRING DIAGRAM

Warning: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the current National Electric Code ANSI/NFPA 70 (in the U.S.), or with the current CSC22.1 Canadian Electric Code (in Canada).

Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup.

Optional Power Heat Duct

Power Supply

 

 

 

Ground

 

 

 

 

(attached to fireplace)

Ground

Ground

 

Green

 

(green)

(green)

 

Green

Optional

 

 

Common

Common

Power In

 

Power

Molex

White

Heat Duct

(white)

(white)

Connector

 

Molex

 

 

 

Hot

Hot

 

 

Connector

 

 

 

(black)

(black)

 

 

 

 

 

 

White

 

 

Blower Snap Disk

 

Black

 

 

 

Black

Fireplace

 

 

 

 

Rheostat

 

Black

 

 

 

Black

 

 

 

 

 

White

 

 

 

 

White

 

 

 

 

Black

 

 

Fireplace

Black

 

 

 

Blowers

 

 

 

 

 

White

 

 

Optional Snap Disk

Black

 

 

Black

 

 

 

 

 

 

Optional Regulator

Blue

 

 

Solenoid (24 V. DC)

Blue

 

 

Gas Control

 

 

 

Valve

 

 

 

(millivolt DC)

 

 

 

Rheostat

 

Blower

 

 

Junction

 

 

 

 

Junction Box

Grounded

 

Box

 

 

 

 

to Blower

 

 

 

 

Ground

Ground

Ground

Ground

 

(green)

(green)

(green)

(green)

 

Common

Common

Common

Common

 

(white)

(white)

(white)

(white)

 

Hot

Hot

Hot

Hot

 

(black)

(black)

(black)

(black)

 

 

 

 

 

Heat Duct

 

 

 

 

Blower

 

Heat Duct

 

 

 

 

Rheostat

 

 

 

 

Ground (green)

 

Optional Second Heat

 

Common (white)

 

Duct (same rheostat and

 

Hot (black)

 

blower wiring as above)

 

 

 

 

3

 

 

 

 

7

 

 

 

 

6

 

 

 

 

9

 

Remote

 

 

1

 

 

 

 

Control

9

 

4

 

Molex

 

 

7

 

8

 

Connector

 

 

 

 

 

 

 

 

11

 

 

 

 

2

 

 

 

 

5

 

 

 

1

 

2

4

3

 

5

7

6

10

8

9

Brown

11

 

12

Red

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Image 53
Contents DV XXL EF Manual Introduction IntroductionImportant Information Travis Industries 4050114 0 0 1 1 4Safety Precautions 4050114 0 0 1 1 4 Travis Industries If YOU Smell GASThis Manual Heating Specifications Natural Gas Propane Features and SpecificationsFeatures Installation Options Additional Items Required Installation WarningsPacking List Recommended Installation Procedure Installation OverviewMinimum Framing Dimensions Fireplace Placement RequirementsVertical Standoff ClearancesRaised Fireplaces Corner InstallationsFuel Gas Line RequirementsGas Line Connection Gas Inlet PressureFireplace junction box Electrical ConnectionAltitude Considerations Vent RequirementsPart Numbers for 8 Diameter Vent Horizontal RunsVertical Vent Requirements Vent InstallationRestrictor Position Approved Vent ConfigurationsElbows Measuring Vent LengthsZero or Two 45 Offsets Four 45 Offsets Vertical Terminations with 0, 2, or 4 45 OffsetsHorizontal Terminations with One Vertical Elbow Horizontal Terminations with Three Vertical Elbows Vertical Terminations with Two Vertical 90 Elbows Termination Requirements see the illustration below Floor Mounted Fireplaces Hearth RequirementsMinimum Top Facing Clearance Facing RequirementsModifying the Face Angle for Rectangular Faces Face DimensionsFireplace Facing Detail Fireplace Facing Example Facing Under 1 ThickArched Faces Facing Example Facing Over 1 ThickMinimum Mantel Clearance Mantel RequirementsCombustible or Non-Combustible Mantels Arch Covers both sides Re-Attaching the Glass FrameGlass Frame Removal and Installation Place the Rear Log Place the Middle Logs Placing the Front Log Placing the Twigs Correct Arch Faces Architectural Faces Before You Begin Location of Controls See explanation below Operation3Starting The Pilot Flame 8OperationTurning the Fireplace On and Off Adjusting the Flame HeightStarting the Fireplace for the First Time Optional Power Heat Duct Adjusting the Blower Speed0Operation Normal Operating SoundsMaintaining Your Fireplaces Appearance Yearly Service ProcedureTroubleshooting Table MaintenanceWhat Prevents Gas Buildup How this Fireplace WorksWhat Turns the Main Burners On and Off Replacement Parts List Wiring DiagramFireplace Xtrordinair 44DVXXL Safety LabelYears 1 & 2 Coverage Parts & Labor 6Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Orifice Identification Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions Modulating Remote Installation6Index