FireplaceXtrordinair 44 DV XXL EF Face Dimensions, Modifying the Face Angle for Rectangular Faces

Page 24

2 4

Installation (for qualified installers only)

Face Dimensions

 

Architectural Faces

Classic Arched

(French Country, Arts & Crafts,

(Gold, Black, or Artisan*)

Art Deco, or Neo-Classical)

6-3/8"

 

Radius = 45-3/8”

 

 

34-1/4”

33-7/8"

 

Access Door

43-3/4”

 

46”

 

 

Access Door

* Artisan faces may vary slightly in size

 

due to the forging process.

 

Metropolitan Face

32-3/8”

45-1/8”

Access Door

Modifying the Face Angle for Rectangular Faces

If using a rectangular face, adjust the face

a

Remove these four

screws from the face

 

 

angle.

angles

Phillips Screwdriver

at the top corners of the glass (see illustration below).

b

Bend the face angle up and replace

the two screws on the upper section.

 

Front of

Fireplace

Glass

c

Straighten the face angle.

Re-bend the face angle at the

d inward location and re-attach the

 

 

 

lower portion with one screw.

24

4050114

1 0 0 - 0 1 1 4 9

Travis Industries

Image 24
Contents DV XXL EF Manual Introduction IntroductionImportant Information Travis Industries 4050114 0 0 1 1 4Safety Precautions If YOU Smell GAS 4050114 0 0 1 1 4 Travis IndustriesThis Manual Features and Specifications Features Installation OptionsHeating Specifications Natural Gas Propane Installation Warnings Packing ListAdditional Items Required Installation Overview Recommended Installation ProcedureFireplace Placement Requirements Minimum Framing DimensionsClearances Vertical StandoffCorner Installations Raised FireplacesGas Line Requirements FuelGas Line Connection Gas Inlet PressureElectrical Connection Fireplace junction boxVent Requirements Altitude ConsiderationsPart Numbers for 8 Diameter Vent Horizontal RunsVent Installation Vertical Vent RequirementsApproved Vent Configurations Restrictor PositionElbows Measuring Vent LengthsVertical Terminations with 0, 2, or 4 45 Offsets Zero or Two 45 Offsets Four 45 OffsetsHorizontal Terminations with One Vertical Elbow Horizontal Terminations with Three Vertical Elbows Vertical Terminations with Two Vertical 90 Elbows Termination Requirements see the illustration below Hearth Requirements Floor Mounted FireplacesFacing Requirements Minimum Top Facing ClearanceFace Dimensions Modifying the Face Angle for Rectangular FacesFireplace Facing Detail Facing Example Facing Under 1 Thick FireplaceFacing Example Facing Over 1 Thick Arched FacesMantel Requirements Combustible or Non-Combustible MantelsMinimum Mantel Clearance Re-Attaching the Glass Frame Arch Covers both sidesGlass Frame Removal and Installation Place the Rear Log Place the Middle Logs Placing the Front Log Placing the Twigs Correct Arch Faces Architectural Faces Operation3 Before You Begin Location of Controls See explanation below8Operation Starting The Pilot FlameAdjusting the Flame Height Starting the Fireplace for the First TimeTurning the Fireplace On and Off Adjusting the Blower Speed Optional Power Heat Duct0Operation Normal Operating SoundsYearly Service Procedure Maintaining Your Fireplaces AppearanceMaintenance Troubleshooting TableHow this Fireplace Works What Turns the Main Burners On and OffWhat Prevents Gas Buildup Wiring Diagram Replacement Parts ListSafety Label Fireplace Xtrordinair 44DVXXL6Limited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyBurner Replacement LP Conversion InstructionsOptional Equipment for qualified installers only Orifice Identification Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Modulating Remote Installation Maintenance Instructions6Index