Optional Equipment (for qualified installers only) 4 9
4Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
aLift the pilot hood off the pilot
assembly.
cRemove the orifice and replace with the LP orifice. Screw the orifice all the way in and replace the pilot hood.
Orifice Identification:
bUse a hex wrench to
unscrew the orifice.
5/32" Hex
NOTE: when
35
LP (Propane) Orifice
35
NG (Natural Gas) Orifice
62
5Install the logs and embers.
6Replace glass and face.
7Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx
Slotted | b |
Screwdriver | |
(or |
|
Remove and discard the
regulator, diaphram, spring
and center post.
c
Install the LP regulator. Use the screws included with the LP regulator. Tighten to approximately 25 Lbs. torque.
Slotted
Screwdriver
(or
d
Place the LP label on the base of the fireplace near the gas control valve.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
8Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly
WARNING: When lighting or
To adjust the pilot flame, turn this screw (NOTE: if totally |
| The pilot flame must contact the thermocouple and |
unscrewed gas will come out of this port). Clockwise |
| thermopile (see the illustration below). Adjust the pilot up or |
lowers the flame while | Standard | down as necessary. |
| Screwdriver |
|
9Inspect the flames. Adjust the air shutter if necessary (see step 7 on page 35).
Travis Industries | 4050114 | 1 0 0 - 0 1 1 4 9 |