Installation (for qualified installers only) | 9 |
Fireplace Placement Requirements
Minimum Framing Dimensions
A 1" clearance is required along the sides and back of the fireplace. The 1"
75" Min.
The fireplace enclosure must not be less than 75" above the base of the fireplace.
If using a remote control or thermostat, route the wire to a location near the gas line (include an extra 3' length for hookup).
Gas line (3/8" M.P.T. or 1/2" F.P.T.) should be routed
Required Firestop (included with the fireplace)
52"
NOTE: if venting directly to the rear, make sure there is a min. 12" space centered behind the fireplace.
3" Clearance Min. (after firestop)
1" Clearance min. to the sides and below the vent (before or after firestop).
Minimum
Route the electrical line to a position at the right rear of the fireplace.
NOTE: If using the power heat vent, allow for the duct passage when framing the enclosure.
•Fireplace must be installed on a level surface capable of supporting the fireplace and vent
•Fireplace must be placed directly on wood or
•Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture and draperies.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location.