FireplaceXtrordinair 44 DV XXL EF manual Fireplace Facing Detail

Page 25

Installation (for qualified installers only)

2 5

Fireplace Facing Detail

NOTE: The overlap is 1-1/2" along the top of the face.

1/4" Arch Faces

Face

Glass

Access Door

1/2"

Air Space

Do not tuck tile underneath the face on the bottom (there will be a 1/2" air space below the access door). You may do this on the sides and top, but not on the bottom.

Make sure these shaded areas are faced over

 

when using the arched face. Rectangular faces

 

must not have tile on the shaded areas (see

 

“Modifying the Face Angle for Rectangular

 

Faces” on the following page)

7-5/8"

27-5/8"

1"

1"

3-7/8"

27-1/2"

31-3/8"

1"

1"

42-3/4”

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Image 25
Contents DV XXL EF Manual Introduction IntroductionImportant Information Travis Industries 4050114 0 0 1 1 4Safety Precautions 4050114 0 0 1 1 4 Travis Industries If YOU Smell GASThis Manual Features Installation Options Features and SpecificationsHeating Specifications Natural Gas Propane Packing List Installation WarningsAdditional Items Required Recommended Installation Procedure Installation OverviewMinimum Framing Dimensions Fireplace Placement RequirementsVertical Standoff ClearancesRaised Fireplaces Corner InstallationsFuel Gas Line RequirementsGas Line Connection Gas Inlet PressureFireplace junction box Electrical ConnectionAltitude Considerations Vent RequirementsPart Numbers for 8 Diameter Vent Horizontal RunsVertical Vent Requirements Vent InstallationRestrictor Position Approved Vent ConfigurationsElbows Measuring Vent LengthsZero or Two 45 Offsets Four 45 Offsets Vertical Terminations with 0, 2, or 4 45 OffsetsHorizontal Terminations with One Vertical Elbow Horizontal Terminations with Three Vertical Elbows Vertical Terminations with Two Vertical 90 Elbows Termination Requirements see the illustration below Floor Mounted Fireplaces Hearth RequirementsMinimum Top Facing Clearance Facing RequirementsModifying the Face Angle for Rectangular Faces Face DimensionsFireplace Facing Detail Fireplace Facing Example Facing Under 1 ThickArched Faces Facing Example Facing Over 1 ThickCombustible or Non-Combustible Mantels Mantel RequirementsMinimum Mantel Clearance Arch Covers both sides Re-Attaching the Glass FrameGlass Frame Removal and Installation Place the Rear Log Place the Middle Logs Placing the Front Log Placing the Twigs Correct Arch Faces Architectural Faces Before You Begin Location of Controls See explanation below Operation3Starting The Pilot Flame 8OperationStarting the Fireplace for the First Time Adjusting the Flame HeightTurning the Fireplace On and Off Optional Power Heat Duct Adjusting the Blower Speed0Operation Normal Operating SoundsMaintaining Your Fireplaces Appearance Yearly Service ProcedureTroubleshooting Table MaintenanceWhat Turns the Main Burners On and Off How this Fireplace WorksWhat Prevents Gas Buildup Replacement Parts List Wiring DiagramFireplace Xtrordinair 44DVXXL Safety LabelYears 1 & 2 Coverage Parts & Labor 6Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Burner ReplacementOptional Equipment for qualified installers only Orifice Identification Power Heat Duct Wall or Ceiling Mounting Optional Equipment for qualified installers only Wiring Diagram Follow the directions below to wire the blower box Maintenance Instructions Modulating Remote Installation6Index