Regency L676 installation manual Horizontal Venting with Two 2 90o Elbows

Page 20

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these options, maximum total

A)

2'

Min.

4' Max.

pipe length is 30 feet with minimum

 

 

 

 

of 6 feet total vertical and maximum

B)

3'

Min.

5' Max.

8 feet total horizontal.

C)

4'

Min.

6' Max.

 

D)

5'

Min.

7' Max.

Please note minimum 1 foot

E)

6' Min.

8' Max.

between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor must be at Set 0 for both NG and LP.

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)2' Min. 1' Max. 3' Min. 2' Max.

B)2' Min. 2' Max. 5' Min. 4' Max.

C)3' Min. 2' Max. 7' Min. 5' Max.

D)4' Min. 3 Max. 9' Min. 6' Max.

E)5' Min. 4' Max. 10' Min. 7' Max.

F)6' Min. 6' Max. 11' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor must be at Set 0 for both NG and LP.

20

Regency® L676 Direct Vent Gas Fireplace

Image 20
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Hearth RequirementsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing Important Header must be metal studUnit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionFactory set for NG units Factory set for LP unitsExterior Vent Termination Requirements Venting Arrangements FPI Kit # Length ContainsInstallation Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Vent must be supported at offsets Feet HeightUnit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Horizontal Termination with Flex Vent SystemGAS Line BACK-UP Battery Installation Hinge Door Heat Shield Power ModulePower Module Heat Shield Latch LocationConversion KIT #521-969 from NG to LP Clip Heat Shield Using a flat head screw driverPilot ShieldHeat J9 Jumper Location J9 JumperHeat Shield Front Burner Bracket Heat Shield Front Burner RemovedHinge Door Rear Log Stand GrateModulating Coil Wires Bottom Brick PanelHeat Shield Bracket Heat ShieldCable Tie Pilot ShieldClip Brick Panel Installation Handle with care. do not Force Into PositionOuterbox of Firebox Bracket Brick Panel Clip Tab Base Brick Panel SlotBackside of Grate LOG SET InstallationRear Burner Tube Front Burner Tube Complete Log Set Installation Aeration Adjustment Wiring DiagramLighting Procedure Operating InstructionsMatching Remote Handset & Control BOX ID Code Operating InstructionsNormal Operating Sounds GAS Appliances Shutdown ProcedureOperation During Power Outage GAS Control Valve Copy of Lighting Plate InstructionsRight Side Exterior Brick Panel Heat ShieldMaintenance BACK-UP Battery Replacement Bracket Hinge Heat DoorPower Module Replacement Bracket Heat ShieldControl Module Control Module ReplacementBracket Hinge Heat Heat Shield Replace the DC sparker DC Sparker ReplacementBattery Cover Valve Tray Replacement Unplug the power sourceModulating coil Carefully remove the bottom brick panelValve Description Parts ListMain Assembly Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Warranty Limited LifetimeInstaller Please complete the following information