Regency L676 installation manual Aeration Adjustment, Wiring Diagram

Page 38

INSTALLATION

INSTALLATION

AERATION

ADJUSTMENT

The burner aeration is factory set but may need

Minimum Air Shutter Opening:

CAUTION: Carbon will be produced if air shutter

adjusting due to either the local gas supply or

NG

Front Burner

1/4"

is tightly closed.

altitude. Open the air shutter for a blue fl ame or

 

close for a more yellow fl ame.

 

Rear Burner

1/8"

Note: Any damage due to carboning

 

LP

Front Burner

5/16"

resulting from improperly setting

In order to adjust the aeration, the logs, grate

the aeration controls is NOT covered

and burners will need to be removed to be able

 

Rear Burner

1/4"

under warranty.

to access the shutters.

 

 

 

 

A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will operate on low, when the unit is running on battery back-up.

WIRING DIAGRAM

(Do not cut the ground terminal off under any circumstances.)

Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

38

Regency® L676 Direct Vent Gas Fireplace

Image 38
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorUnit Dimensions Installation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Heat Release KITHearth Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing Important Header must be metal studUnit Assembly Prior to InstallationFactory set for NG units Venting IntroductionVent Restrictor Position Factory set for LP unitsExterior Vent Termination Requirements Venting Arrangements FPI Kit # Length ContainsInstallation Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Vent must be supported at offsets Feet HeightUnit Installation with Horizontal Termination Diagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Horizontal Termination with Flex Vent SystemGAS Line Power Module BACK-UP Battery InstallationHinge Door Heat Shield Power Module Heat Shield Latch LocationConversion KIT #521-969 from NG to LP Clip Heat Shield Using a flat head screw driverPilot ShieldHeat J9 Jumper Location J9 JumperHinge Door Heat Shield Front BurnerBracket Heat Shield Front Burner Removed Rear Log Stand GrateHeat Shield Modulating Coil WiresBottom Brick Panel Bracket Heat ShieldCable Tie Pilot ShieldClip Brick Panel Installation Handle with care. do not Force Into PositionOuterbox of Firebox Bracket Brick Panel Clip Tab Base Brick Panel SlotBackside of Grate LOG SET InstallationRear Burner Tube Front Burner Tube Complete Log Set Installation Aeration Adjustment Wiring DiagramMatching Remote Handset & Control BOX ID Code Lighting ProcedureOperating Instructions Operating InstructionsNormal Operating Sounds GAS Appliances Shutdown ProcedureOperation During Power Outage Right Side Exterior Brick Panel GAS Control ValveCopy of Lighting Plate Instructions Heat ShieldMaintenance BACK-UP Battery Replacement Bracket Hinge Heat DoorPower Module Replacement Bracket Heat ShieldControl Module Control Module ReplacementBracket Hinge Heat Heat Shield Replace the DC sparker DC Sparker ReplacementBattery Cover Valve Tray Replacement Unplug the power sourceModulating coil Carefully remove the bottom brick panelValve Description Parts ListMain Assembly Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Warranty Limited LifetimeInstaller Please complete the following information