Regency L676 BACK-UP Battery Installation, Heat Shield Latch Location, Bracket, Power Module

Page 27

INSTALLATION

BACK-UP BATTERY INSTALLATION

(within Power Module)

The 9V battery operates the rear burner under power outage conditions.

The AA battery operates the DC Sparker for lighting the pilot.

1) Remove the glass door.

2) Loosen the 2 screws that hold the left side

4)

Unplug the power source.

 

heat shield in place.

5)

Loosen the bottom screw and remove the

a. Release the 2 door latches on the left

 

and right side at the top of the fi rebox.

 

 

top screw from the power module.

 

 

 

INSTALLATION

Heat

Shield

Latch Location

Latch

3) Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

Hinge

Door

Heat

Shield

Power

Module

6)Cut the cable tie that holds together the wires for the power module and the pull out the power module.

7)Remove the power module cover by removing the 2 screws, one on each side.

Power Module

8)Install the 9V battery and the AA battery.

Regency® L676 Direct Vent Gas Fireplace

27

Image 27
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Heat Release KITHearth Requirements Manufactured Mobile Home Additional RequirementsClearances Mantel LEG Clearances Mantel ClearancesImportant Header must be metal stud Framing & FinishingPrior to Installation Unit AssemblyFactory set for LP units Venting IntroductionVent Restrictor Position Factory set for NG unitsExterior Vent Termination Requirements FPI Kit # Length Contains Venting ArrangementsRigid Pipe Venting Systems Installation58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Feet Height Vent must be supported at offsetsUnit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramHorizontal Termination with Flex Vent System Unit InstallationGAS Line Heat Shield Latch Location BACK-UP Battery InstallationHinge Door Heat Shield Power Module Power ModuleConversion KIT #521-969 from NG to LP Using a flat head screw driver Pilot ShieldHeatClip Heat Shield J9 Jumper J9 Jumper LocationRear Log Stand Grate Heat Shield Front BurnerBracket Heat Shield Front Burner Removed Hinge DoorBracket Heat Shield Modulating Coil WiresBottom Brick Panel Heat ShieldPilot Shield ClipCable Tie Handle with care. do not Force Into Position Brick Panel InstallationBracket Brick Panel Clip Tab Base Brick Panel Slot Outerbox of FireboxLOG SET Installation Rear Burner Tube Front Burner TubeBackside of Grate Complete Log Set Installation Wiring Diagram Aeration AdjustmentOperating Instructions Lighting ProcedureOperating Instructions Matching Remote Handset & Control BOX ID CodeShutdown Procedure Operation During Power OutageNormal Operating Sounds GAS Appliances Heat Shield GAS Control ValveCopy of Lighting Plate Instructions Right Side Exterior Brick PanelMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementBracket Heat Shield Power Module ReplacementControl Module Replacement Bracket Hinge HeatControl Module DC Sparker Replacement Battery CoverHeat Shield Replace the DC sparker Unplug the power source Valve Tray ReplacementCarefully remove the bottom brick panel ValveModulating coil Parts List Main AssemblyDescription Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Limited Lifetime WarrantyInstaller Please complete the following information