Regency L676 installation manual Vertical Venting with Two 2 90o Elbows

Page 21

INSTALLATION

Vertical Venting with Two (2) 90o Elbows

INSTALLATION

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 With these options, max. total pipe

A)2' Min. 2' Max. 3' Min. length is 30 feet with min. of 6 feet total vertical and max. 8 feet total

B)2' Min. 10' Max. 6' Min. horizontal.

C)3' Min. 6' Max. 4' Min.

D)4' Min. 7' Max. 5' Min. Please note min. 1 foot between

E)5' Min. 8' Max. 6' Min. 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor must be at Set 0 for both NG and LP.

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V H + H1 V + V1

A)2' Min. 2' Max. 4' Min.

B)3' Min. 4' Max. 6' Min.

C)4' Min. 5' Max. 7' Min.

D)5' Min. 6' Max. 8' Min.

E)6' Min. 8' Max. 9' Min.

With these options, max. total pipe length is 30 feet with min. of 9 feet total vertical and max. 8 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor must be at Set 0 for both NG and LP.

Regency® L676 Direct Vent Gas Fireplace

21

Image 21
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions General Safety Information InstallationInstallation Checklist Important Message Save These InstructionsHearth Requirements Heat Release KITManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesImportant Header must be metal stud Framing & FinishingPrior to Installation Unit AssemblyVent Restrictor Position Venting IntroductionFactory set for NG units Factory set for LP unitsExterior Vent Termination Requirements FPI Kit # Length Contains Venting ArrangementsRigid Pipe Venting Systems Installation58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Feet Height Vent must be supported at offsetsUnit Installation with Horizontal Termination This allows for small adjustments Unit Installation With Vertical TerminationDiagram Minimum VentHorizontal Termination with Flex Vent System Unit InstallationGAS Line Hinge Door Heat Shield Power Module BACK-UP Battery InstallationPower Module Heat Shield Latch LocationConversion KIT #521-969 from NG to LP Using a flat head screw driver Pilot ShieldHeatClip Heat Shield J9 Jumper J9 Jumper LocationBracket Heat Shield Front Burner Removed Heat Shield Front BurnerHinge Door Rear Log Stand GrateBottom Brick Panel Modulating Coil WiresHeat Shield Bracket Heat ShieldPilot Shield ClipCable Tie Handle with care. do not Force Into Position Brick Panel InstallationBracket Brick Panel Clip Tab Base Brick Panel Slot Outerbox of FireboxLOG SET Installation Rear Burner Tube Front Burner TubeBackside of Grate Complete Log Set Installation Wiring Diagram Aeration AdjustmentOperating Instructions Lighting ProcedureMatching Remote Handset & Control BOX ID Code Operating InstructionsShutdown Procedure Operation During Power OutageNormal Operating Sounds GAS Appliances Copy of Lighting Plate Instructions GAS Control ValveRight Side Exterior Brick Panel Heat ShieldMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementBracket Heat Shield Power Module ReplacementControl Module Replacement Bracket Hinge HeatControl Module DC Sparker Replacement Battery CoverHeat Shield Replace the DC sparker Unplug the power source Valve Tray ReplacementCarefully remove the bottom brick panel ValveModulating coil Parts List Main AssemblyDescription Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Limited Lifetime WarrantyInstaller Please complete the following information