25)Remove the pilot shield by removing the 2 screws.

Pilot

Shield

30)Ensure that the new rubber gasket (supplied with coil) is properly positioned and install the new modulating pressure regulator assem- bly to the valve using the screws supplied with the kit. Tighten screws securely.

INSTALLATION

26)Remove the clip from the pilot head assembly using a flat head screw driver.

Clip

27)Remove the NG pilot orifice with the Allen Key and replace with LP pilot orifice.

28)Re-install the pilot head and pilot shield.

29)Using a Torx T20, remove and discard the 3 pressure regulator mounting screws. Remove the modulator coil and the gasket.

31)Install the enclosed identification label to the valve body where it can be easily seen.

32)Attach the LP conversion decal near or on top of the serial no. decal.

33)Replace yellow "Natural Gas" label with red "Propane" label.

34)Re-install valve tray and all electrical connections to the valve and solenoid valve.

35)Cut the cable tie that holds the wires connected to the Control Module and pull out.

Note: An extra cable tie is included with the LP Kit for re-installation.

Cable Tie

Control Module

 

36)Remove the J9 jumper using needle nose pliers.

J9 Jumper

37)Re-install the control module.

38)Re-install the base brick panel.

39)Re-install the rear log support bracket.

40)Plug in the power source.

41)Re-install the left heat shield.

42)Install the interior brick panels.

43)Adjust the burner aeration settings to the LP settings and install the burners.

Front Burner

5/16"

Rear Burner

1/4"

44)Re-install the grate.

45)Turn on the gas supply and check for gas leaks.

46)Install the log set.

47)Re-install the glass door.

48)Check the inlet (12" WC) and outlet (10"WC).

49)Re-install the right heat shield.

50)Check operation of flame control using the remote control. Refer to FireWizard operation manual for details.

51)Check for proper flame appearance.

52)Install the exterior brick panels.

Installer Notice:

This instructions must be left with the appliance.

J9 Jumper Location

Regency® L676 Direct Vent Gas Fireplace

33

Image 33
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions General Safety Information InstallationInstallation Checklist Important Message Save These InstructionsHearth Requirements Heat Release KITManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesImportant Header must be metal stud Framing & FinishingPrior to Installation Unit AssemblyVent Restrictor Position Venting IntroductionFactory set for NG units Factory set for LP unitsExterior Vent Termination Requirements FPI Kit # Length Contains Venting ArrangementsRigid Pipe Venting Systems Installation58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Feet Height Vent must be supported at offsetsUnit Installation with Horizontal Termination This allows for small adjustments Unit Installation With Vertical TerminationDiagram Minimum VentHorizontal Termination with Flex Vent System Unit InstallationGAS Line Hinge Door Heat Shield Power Module BACK-UP Battery InstallationPower Module Heat Shield Latch LocationConversion KIT #521-969 from NG to LP Using a flat head screw driver Pilot ShieldHeatClip Heat Shield J9 Jumper J9 Jumper LocationBracket Heat Shield Front Burner Removed Heat Shield Front BurnerHinge Door Rear Log Stand GrateBottom Brick Panel Modulating Coil WiresHeat Shield Bracket Heat ShieldPilot Shield ClipCable Tie Handle with care. do not Force Into Position Brick Panel InstallationBracket Brick Panel Clip Tab Base Brick Panel Slot Outerbox of FireboxLOG SET Installation Rear Burner Tube Front Burner TubeBackside of Grate Complete Log Set Installation Wiring Diagram Aeration AdjustmentOperating Instructions Lighting ProcedureMatching Remote Handset & Control BOX ID Code Operating InstructionsShutdown Procedure Operation During Power OutageNormal Operating Sounds GAS Appliances Copy of Lighting Plate Instructions GAS Control ValveRight Side Exterior Brick Panel Heat ShieldMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementBracket Heat Shield Power Module ReplacementControl Module Replacement Bracket Hinge HeatControl Module DC Sparker Replacement Battery CoverHeat Shield Replace the DC sparker Unplug the power source Valve Tray ReplacementCarefully remove the bottom brick panel ValveModulating coil Parts List Main AssemblyDescription Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Limited Lifetime WarrantyInstaller Please complete the following information