Regency L676 installation manual BACK-UP Battery Replacement, Bracket Hinge Heat Door

Page 43

MAINTENANCE

BACK-UP BATTERY REPLACEMENT

(within Power Module)

1)Remove the exterior brick panels.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Latch Location

Latch

3)Loosen the 2 screws that hold the left side heat shield in place.

Heat

Shield

7)Pull out the power module.

8)Remove the power module cover by removing the 2 screws, one on each side.

Power Module

9)Replace the 9V battery and the AA battery.

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

4)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

NOTE: The9Vbatteryoperatestherearburner under power outage conditions. The AA battery operates the DC Sparker for lighting the pilot.

Hinge

Heat

Door

Shield

5) Unplug the power source.

6) Loosen the bottom screw and remove the top screw from the power module.

10)Reverse steps to re-install.

MAINTENANCE

Power

Module

Regency® L676 Direct Vent Gas Fireplace

43

Image 43
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Heat Release KITHearth Requirements Manufactured Mobile Home Additional RequirementsClearances Mantel LEG Clearances Mantel ClearancesImportant Header must be metal stud Framing & FinishingPrior to Installation Unit AssemblyFactory set for LP units Venting IntroductionVent Restrictor Position Factory set for NG unitsExterior Vent Termination Requirements FPI Kit # Length Contains Venting ArrangementsRigid Pipe Venting Systems Installation58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Feet Height Vent must be supported at offsetsUnit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramHorizontal Termination with Flex Vent System Unit InstallationGAS Line Heat Shield Latch Location BACK-UP Battery InstallationHinge Door Heat Shield Power Module Power ModuleConversion KIT #521-969 from NG to LP Pilot ShieldHeat Using a flat head screw driverClip Heat Shield J9 Jumper J9 Jumper LocationRear Log Stand Grate Heat Shield Front BurnerBracket Heat Shield Front Burner Removed Hinge DoorBracket Heat Shield Modulating Coil WiresBottom Brick Panel Heat ShieldClip Pilot ShieldCable Tie Handle with care. do not Force Into Position Brick Panel InstallationBracket Brick Panel Clip Tab Base Brick Panel Slot Outerbox of FireboxRear Burner Tube Front Burner Tube LOG SET InstallationBackside of Grate Complete Log Set Installation Wiring Diagram Aeration AdjustmentOperating Instructions Lighting ProcedureOperating Instructions Matching Remote Handset & Control BOX ID CodeOperation During Power Outage Shutdown ProcedureNormal Operating Sounds GAS Appliances Heat Shield GAS Control ValveCopy of Lighting Plate Instructions Right Side Exterior Brick PanelMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementBracket Heat Shield Power Module ReplacementBracket Hinge Heat Control Module ReplacementControl Module Battery Cover DC Sparker ReplacementHeat Shield Replace the DC sparker Unplug the power source Valve Tray ReplacementValve Carefully remove the bottom brick panelModulating coil Main Assembly Parts ListDescription Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Limited Lifetime WarrantyInstaller Please complete the following information