INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fi replace are defi ned by standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Clearance to Combustibles from:
Back | 0" | (0mm) |
Side | 0" | (0mm) |
Floor | 0" | (0mm) |
Minimum Clearance from Top of Front Facing:
Mantel | min. | (419mm) |
Ceiling | 52" | (813mm) from top of front facing |
Side Wall to Unit:
15"* (381mm)
Horizontal Vent Clearances to Combustibles:
Top | 3" | (76mm) |
Side | 2" | (51mm) |
Bottom | 2" | (51 mm) |
Vertical Vent Clearances to Combustibles:
All Sides | 2" | (51mm) |
Alcove Clearances:
Min. Depth | 36" | (914mm) |
Min. Width* | 84" | (2134mm) |
Min. Height | 84" | (2032mm) |
* Alcove side wall must have a minimum of 15" (381mm) clearance on one side.
WARNING |
| IMPORTANT |
Fire hazard is an extreme risk |
|
|
if these clearances (air space) to combustible materials |
| If converting this unit to LP, it is highly recommened |
are not adhered to. It is of greatest importance that this |
| |
fireplace and vent system be installed only in |
| the conversion be done BEFORE the unit is slid into |
accordance with these instructions. |
| position for ease of conversion. See "Conversion |
|
| from NG to LP" section for instructions. |
| ||
|
|
|
INSTALLATION
Regency® L676 Direct Vent Gas Fireplace | 9 |