17)Ensure that the new rubber gasket (supplied with coil) is properly positioned and install the new modulating pressure regulator as- sembly to the valve using the screws sup- plied with the kit. Tighten screws securely.
18)Install the enclosed identification label to the valve body where it can be easily seen.
19)Attach the LP conversion decal near or on top of the serial no. decal.
20)Replace yellow "Natural Gas" label with red "Propane" label.
21)
22)Remove the left side panel by undoing the 8 screws.
23)Locate the control box shown below and remove the J9 jumper using needle nose pliers.
J9 Jumper Location
24)
25)
26)Adjust the burner aeration settings to the LP settings and install the burners.
Front Burner | 5/16" |
Rear Burner | 1/4" |
27)
28)
29)
30)Continue with completing unit installation.
NOTE: Once the unit has been installed;
a)Turn on the gas supply and check for gas leaks.
b)Check the inlet (12" WC) and outlet (10"WC).
c)Check operation of flame control using the remote control. Refer to FireWizard operation manual for details.
d)Check for proper flame appearance.
Installer Notice:
This instructions must be left with the appliance.
J9 Jumper