Regency L676 LOG SET Installation, Rear Burner Tube Front Burner Tube, Backside of Grate

Page 36

INSTALLATION

LOG SET INSTALLATION

Installation of Interior Brick Panels must be completed before installing the log set.

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.

Log kit (Part No. 521-930 and 521-935) contain the following pieces:

a)

03-25

Log Rear

b)

03-26

Log Top

c)03-27 Log Front Left

d)03-28 Log Front Right

e)902-154 Embers Lava

f)902-179 Vermiculite

03-25

03-27

03-28

3)Place log 03-27 on the front left side of the burner. Place the right end of the log into the pin and rest the left end of the log inbetween the rear and front burner tubes.

03-27

Rear

Burner

Tube

Front Burner Tube

4)Place the left end of log 03-28 into the pin while resting the right end of the log on the grate. Slide the right end of the log forward until it is approximately 3/8" away from the back side of the grate.

03-28

03-26

The "03" reference numbers (i.e. 03-25) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Place log 03-25 on the rear log support pins.

Backside of Grate

5) Line up the two holes on the underside of log 03-26 with the pins on logs 03-25 and 03-27 and fit in place.

03-26

03-25

03-25

03-27

36

Regency® L676 Direct Vent Gas Fireplace

Image 36
Contents Libertytm L676 Gas Fireplace Manufactured Mobile Home Requirements Table of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Hearth RequirementsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing Important Header must be metal studUnit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionFactory set for NG units Factory set for LP unitsExterior Vent Termination Requirements Venting Arrangements FPI Kit # Length ContainsInstallation Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Vent must be supported at offsets Feet HeightUnit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Horizontal Termination with Flex Vent SystemGAS Line BACK-UP Battery Installation Hinge Door Heat Shield Power ModulePower Module Heat Shield Latch LocationConversion KIT #521-969 from NG to LP Using a flat head screw driver Pilot ShieldHeatClip Heat Shield J9 Jumper Location J9 JumperHeat Shield Front Burner Bracket Heat Shield Front Burner RemovedHinge Door Rear Log Stand GrateModulating Coil Wires Bottom Brick PanelHeat Shield Bracket Heat ShieldPilot Shield ClipCable Tie Brick Panel Installation Handle with care. do not Force Into PositionOuterbox of Firebox Bracket Brick Panel Clip Tab Base Brick Panel SlotLOG SET Installation Rear Burner Tube Front Burner TubeBackside of Grate Complete Log Set Installation Aeration Adjustment Wiring DiagramLighting Procedure Operating InstructionsMatching Remote Handset & Control BOX ID Code Operating InstructionsShutdown Procedure Operation During Power OutageNormal Operating Sounds GAS Appliances GAS Control Valve Copy of Lighting Plate InstructionsRight Side Exterior Brick Panel Heat ShieldMaintenance BACK-UP Battery Replacement Bracket Hinge Heat DoorPower Module Replacement Bracket Heat ShieldControl Module Replacement Bracket Hinge HeatControl Module DC Sparker Replacement Battery CoverHeat Shield Replace the DC sparker Valve Tray Replacement Unplug the power sourceCarefully remove the bottom brick panel ValveModulating coil Parts List Main AssemblyDescription Parts List Burner & LOG Assembly Parts List Parts List Parts List Warranty Warranty Limited LifetimeInstaller Please complete the following information