4.Gas orifice spuds are stamped with a number on the side. Replace the LP gas orifice spud with the correct Natural gas orifice spud.
XXX | A |
|
A. Stamped number
Refer to the following chart for the correct Natural gas orifice spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
Burner Location | Burner Rating | Size | |
Right front | 6,000 | Btu/h | 1.10 mm |
Left front | 14,000 | Btu/h | 1.70 mm |
Right rear | 12,500 | Btu/h | 1.61 mm |
Left rear | 6,000 | Btu/h | 1.10 mm |
|
|
|
|
5.Place LP gas orifice spuds in plastic parts bag for future use and keep with package containing literature.
6.Replace burner cap.
7.Repeat steps
To Convert TripleTier® Flame Burner (on some models)
1.Remove burner cap.
2.Remove the burner head using a size T20® TORX® screwdriver.
3.Remove the plate on the external gas orifice spud.
A
B
C
D
A. Burner caps
B. Burner heads
C. External gas orifice spud access plate
D. Internal gas orifice spud
IMPORTANT: The TripleTier® Flame burner has 2 gas orifice spuds. Do not forget to change the external gas orifice spud located under the plate.
A
B
C
A.Plate
B.External gas orifice spud
C.Internal gas orifice spud
4.Apply masking tape to the end of a 7 mm nut driver to help hold the internal gas orifice spud in the nut driver while changing it. Press nut driver down onto the internal gas orifice spud and remove by turning it counterclockwise and lifting out. Set internal gas orifice spud aside.
5.Use a 7 mm combination wrench to remove the external orifice spud. Turn counterclockwise to remove. Set external gas orifice spud aside.
6.Replace each LP gas orifice spud with the correct Natural gas orifice spud. Refer to the following chart for correct Natural gas orifice spud placement.
Natural Gas Orifice Spud Chart for TripleTier® Flame Burners
Burner Location | Burner Rating | Size | |
Left front (external | 12,200 | Btu/h | 1.70 mm |
TripleTier® burner) |
|
|
|
|
|
|
|
Left front (internal | 2,800 | Btu/h | 0.70 mm |
TripleTier® burner) |
|
|
|
|
|
|
|
7.Replace burner plate, head and cap.
8.Place LP gas orifice spuds in plastic parts bag for future use and keep with package containing literature.
To Convert Oven Bake Burner
1.Remove oven racks.
2.Use a ½" combination wrench to loosen the orifice hood away from the pin (about 2 to 2½ turns). The oven bake burner flame cannot be properly adjusted if this conversion is not made. See “Adjust Oven Bake Flame” in the “Electronic Ignition System” section.
A
B
A
A
A. Orifice hood
B. Pin
21