4.Gas orifice spuds are stamped with a number on the side. Replace the LP gas orifice spud with the correct Natural gas orifice spud.

XXX

A

 

A. Stamped number

Refer to the following chart for the correct Natural gas orifice spud placement.

Natural Gas Orifice Spud Chart for Standard Surface Burners

Burner Location

Burner Rating

Size

Right front

6,000

Btu/h

1.10 mm

Left front

14,000

Btu/h

1.70 mm

Right rear

12,500

Btu/h

1.61 mm

Left rear

6,000

Btu/h

1.10 mm

 

 

 

 

5.Place LP gas orifice spuds in plastic parts bag for future use and keep with package containing literature.

6.Replace burner cap.

7.Repeat steps 1-6 for the remaining burners, except for the TripleTier® Flame burner (on some models). See “To Convert TripleTier® Flame Burners” in the “Natural Gas Conversion” section.

To Convert TripleTier® Flame Burner (on some models)

1.Remove burner cap.

2.Remove the burner head using a size T20® TORX® screwdriver.

3.Remove the plate on the external gas orifice spud.

A

B

C

D

A. Burner caps

B. Burner heads

C. External gas orifice spud access plate

D. Internal gas orifice spud

IMPORTANT: The TripleTier® Flame burner has 2 gas orifice spuds. Do not forget to change the external gas orifice spud located under the plate.

A

B

C

A.Plate

B.External gas orifice spud

C.Internal gas orifice spud

4.Apply masking tape to the end of a 7 mm nut driver to help hold the internal gas orifice spud in the nut driver while changing it. Press nut driver down onto the internal gas orifice spud and remove by turning it counterclockwise and lifting out. Set internal gas orifice spud aside.

5.Use a 7 mm combination wrench to remove the external orifice spud. Turn counterclockwise to remove. Set external gas orifice spud aside.

6.Replace each LP gas orifice spud with the correct Natural gas orifice spud. Refer to the following chart for correct Natural gas orifice spud placement.

Natural Gas Orifice Spud Chart for TripleTier® Flame Burners

Burner Location

Burner Rating

Size

Left front (external

12,200

Btu/h

1.70 mm

TripleTier® burner)

 

 

 

 

 

 

 

Left front (internal

2,800

Btu/h

0.70 mm

TripleTier® burner)

 

 

 

 

 

 

 

7.Replace burner plate, head and cap.

8.Place LP gas orifice spuds in plastic parts bag for future use and keep with package containing literature.

To Convert Oven Bake Burner

1.Remove oven racks.

2.Use a ½" combination wrench to loosen the orifice hood away from the pin (about 2 to 2½ turns). The oven bake burner flame cannot be properly adjusted if this conversion is not made. See “Adjust Oven Bake Flame” in the “Electronic Ignition System” section.

A

B

A

A

A. Orifice hood

B. Pin

21

Image 21 Contents
W10526089A Table DES Matières Range SafetyWhat to do if YOU Smell GAS Tools and Parts Installation RequirementsParts needed Tools neededMobile Home Additional Installation Requirements Mobile home installations requireLocation Requirements Slide-in Range Product Dimensions Freestanding RangeInstallation Clearances Freestanding RangesSlide-In Ranges Gas Supply Requirements Electrical RequirementsType of Gas Gas Supply LineCountertop Preparation Gas Supply Pressure TestingBurner Input Requirements Gas Pressure RegulatorUnpack Range Installation InstructionsMeasure for Proper Height Slide-In RangesInstall Anti-Tip Bracket Adjust Leveling LegsFloor Mounting Wall MountingRemove Warming or Storage Drawer Verify Anti-Tip Bracket Is Installed EngagedLevel Range To Remove Warming DrawerTypical flexible connection Make Gas ConnectionTypical rigid pipe connection Complete ConnectionElectronic Ignition System Initial lighting and gas flame adjustmentsCheck Operation of Cooktop Burners Standard Surface Burners TripleTier Flame BurnerAdjust Oven Bake Flame if needed Adjust Flame Height Check Operation of Oven Bake BurnerTo adjust standard burners If the low flame needs to be adjustedReplace Oven Racks and Warming or Storage Drawer Complete Installation LP Gas Conversion GAS Conversions To Convert Gas Pressure Regulator Turn manual shutoff valve to the closed positionTo Convert TripleTier Flame Burners on some models To Convert Standard Surface BurnersGas pressure regulator Remove plastic cover from gas pressure regulator capTo Convert Oven Bake Burner To Convert Oven Broil BurnerPlate External gas orifice spud Internal gas orifice spud Locking screw Orifice hoodNatural Gas Conversion Stamped number To Convert TripleTier Flame Burner on some modelsTo Convert Oven Broil Burner Votre sécurité et celle des autres est très importante Sécurité DE LA CuisinièrePied de La cuisinière Exigences D’INSTALLATION Exigences demplacementOutillage et pièces 64 cm Dimensions du produit Cuisinière autoportanteCuisinière encastrable 30⁹⁄₁₆ 77,6 cm 30 76,2 cm ³⁄₄ 14,6 cm B 76,2 cmDégagements de séparation à respecter Cuisinières autoportantesCuisinières encastrables Spécifications de l’alimentation en gaz Spécifications électriquesType de gaz Gaz naturelDétendeur Canalisation dalimentation en gazDébit thermique des brûleurs Tests de pressurisation de la canalisation de gazPréparation du plan de travail Instructions DinstallationDéballage de la cuisinière Mesures pour une hauteur appropriéeRéglage des pieds de nivellement Installation de la bride antibasculementRetrait du tiroir-réchaud Retrait du tiroir-réchaud ou du tiroir De remisageRetrait du tiroir de remisage Montage au plancherSur les modèles avec tiroir de remisage Réglage de laplomb de la cuisinièreSur les modèles avec tiroir-réchaud Sur les cuisinières équipées de tiroirs de remisageRaccordement typique par raccord flexible Raccordement à la canalisation de gazRaccordement typique à une canalisation rigide Compléter le raccordementCuisinière encastrable Système dallumage électroniqueAllumage initial et réglages des flammes Brûleur TripleTierRéglage de la taille des flammes Si le brûleur ne sallume pas correctementContrôle du fonctionnement du brûleur de cuisson au four Réglage des brûleurs standardRéinstallation du tiroir de remisage Réinstallation du tiroir-réchaudContrôle du fonctionnement du brûleur du gril Sil est nécessaire de régler la taille des flammesAchever l’installation Si vous avez besoin dassistance ou de serviceSi la cuisinière ne fonctionne pas, contrôler ce qui suit Conversion pour lalimentation au propane Conversions Pour Changement DE GAZConversion du détendeur Important Ne pas enlever le détendeurDétendeur Conversion des brûleurs standard de la table de cuissonConversion du brûleur du gril Conversion du brûleur de cuisson au fourPlaque Gicleur externe Gicleur interne Injecteur femelle BrocheConversion des brûleurs standard de surface Conversion pour lalimentation au gaz naturelChiffre gravé Ôter les grilles du four