1.Verify the minimum and maximum gas supply pressures for the type of gas to be used in accordance with the accompanying tables:
Non-CE Standard
for Incoming Gas Pressures
|
| Gas | M inim um | M axim um |
|
|
|
|
|
| 6" W.C. | 14" W.C. |
|
|
|
|
| Natural | 1.49 kPa | 3.48 kPa |
|
|
|
|
|
| 14.93 mbar | 34.84 mbar |
|
|
|
|
|
| 11" W.C. | 14" W.C. |
|
|
|
|
| LP | 2.74 kPa | 3.48 kPa |
|
|
|
|
|
| 27.37 mbar | 34.84 mbar |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CE Standard
for Incoming Gas Pressures
| Pressure |
| Regulator |
|
|
Gas | (mbar)(1) | Orifice Diameter | Pressure | Consum ption |
|
G20 | 20 | 18 x 1,40 mm | 7,5 mbar | 3,00 m3/h |
|
G25 | 20 - 25 | 18 x 1,40 mm | 10 mbar | 3,50 m3/h |
|
G31 | 37 - 50 | 18 x 0,86 mm | 20,6 mbar | 2,21 kg/h |
|
(1) mbar = 10,2 mm H2O
7.For fryers equipped with a FootPrint III system or basket lifts, plug the electrical cord(s) into a power receptacle behind the fryer.
2.4Connection to Gas Line
DANGER
Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas controls will cause improper and dangerous operation.
DANGER
When
DANGER
All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main
DANGER
The 47 Series fryer has received the CE mark for the countries and gas categories indicated in the accompanying table: