Frymaster 47 Series Converting to Another Gas Type, Dual-Vat, Honeywell Gas Valves

Page 17

14.Reinstall and secure the fryer control panel. Loosen the temperature dial plate screws and rotate the dial until the 325°F (162°C) index mark is at the 12 o’clock position, then retighten the screws.

15.Reinstall the thermostat knob with its pointer aligned with the 325°F (162°C) index mark on the temperature dial plate. Tighten the thermostat knob set screws to prevent slippage.

2.5Converting to Another Gas Type

"47" Series fryers are configured at the factory for either natural gas or Propane (LP) gas. A gas conversion kit must be installed by a Factory Authorized Service Center technician when converting from one type of gas to another.

DANGER

This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific gas-conversion components. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.7 of this manual.

CE Gas Conversion Kits

Full-Vat

Natural to LP: 826-1462 (includes .86mm orifice, P/N 810-0340)

LP to Natural: 826-1463 (includes 1.40mm orifice, P/N 810-0330)

Dual-Vat

Natural to LP: 826-1464 (includes .80mm orifice, P/N 810-1040)

LP to Natural: 826-1465 (includes 1.30mm orifice, P/N 810-0131)

Non-CE Gas Conversion Kits

Robertshaw Gas Valves

Natural to LP: 826-0962 [for dual-vatconfigurations, order P/N 817-0098 (Qty-1) and P/N 810- 0148 (Qty-1) in addition to the kit]

LP to Natural: 826-0963 [for dual-vatconfigurations, order P/N 810-0187 (Qty-1) and P/N 810- 0149 (Qty-1) in addition to the kit]

Honeywell Gas Valves

Natural to LP: 826-1143 [for dual-vatconfigurations, order P/N 807-1846 (Qty-1) and P/N 810- 0148 (Qty-1) in addition to the kit]

LP to Natural: 826-1144 [for dual-vatconfigurations, order P/N 807-1849 (Qty-1) and P/N 810- 0149 (Qty-1) in addition to the kit]

2-9

Image 17
Contents Series Gas Fryers Hour Service HotlineCanada Page Series GAS Fryers Table of Contents Series GAS Fryers General Information Parts Ordering and Service InformationApplicability and Validity Retain and Store this Manual in a Safe Place for Future USEEquipment Description Safety InformationEuropean Community CE Specific Information Definitions Installation, Operating, and Service PersonnelWhat to do if your equipment arrives damaged Shipping Damage Claim ProcedureClearance and Ventilation Series GAS Fryers Installation InstructionsGeneral Installation Requirements Electrical Grounding Requirements National Code RequirementsFCC Compliance Caster/Leg InstallationPage CE Standard For Incoming Gas Pressures Non-CE Standard For Incoming Gas PressuresCE Standard CE Standard Burner Manifold Gas Pressures Page Dual-Vat Converting to Another Gas TypeNon-CE Gas Conversion Kits Robertshaw Gas Valves Honeywell Gas ValvesCE and Non-CE Gas Conversion Instructions Lighting the Pilot on NON-EUROPEAN NON-CE Fryers Accessing the PilotSeries GAS Fryers Operating Instructions Pilot Button OFF Button For units equipped with Thermostat Controls Placing the Fryer Into OperationFor units equipped with other than Thermostat Controls Boiling-Out the FrypotPage Controller Operation and Programming Series GAS Fryers Filtration Instructions Page Page Snap the Power Shower into the frypot Page Page Fryer Preventive Maintenance Checks and Services Series GAS Fryers Preventive MaintenanceDaily Checks and Services Weekly Checks and ServicesClean Detachable Parts and Accessories Quarterly Checks and ServicesDrain and Clean Frypot Check Computer Magic III Set Point Accuracy Clean Gas Valve Vent TubeCheck Thermostat Controller Thermostat Calibration Fryer SEMI-ANNUAL Checks and ServicesCheck Burner Manifold Pressure Built-In Filtration System Page Introduction Series GAS Fryers Operator TroubleshootingProblem Probable Causes Corrective Action Probable Causes Corrective Action Troubleshooting Fryers with Thermostat ControlsProblem Troubleshooting the Built-In Filtration System Troubleshooting Abnormal Burner OperationTransfer takes place Pump starts, but noOr the transfer is Very slowSpraying properly Power Shower is notReplacing the Controller or Controller Wiring Harness This page Intentionally Left Blank Service Hotline