6.2Troubleshooting Fryers with Solid State (Analog), Digital, or CM III Controllers or Basket Lift Timers
PROBLEM | PROBABLE CAUSES |
| CORRECTIVE ACTION | |
| A. Pilot not lit (units w/pilot ignition | A. Light pilot per instructions in | ||
| only). |
| Chapter 3 of this manual. | |
| B. Drain valve open. | B. Verify that drain valve is fully | ||
|
| closed. | ||
|
|
| ||
| C. No electrical power to unit. | C. Verify that unit is plugged in and | ||
|
| that circuit breaker is not tripped. | ||
|
|
| ||
|
| D. Verify that the gas line quick | ||
|
|
| disconnect is properly connected, | |
Burner will not | D. No gas being supplied to unit. |
| that any cutoff valves between the | |
| fryer and the gas main are open, | |||
light. |
|
| and that the main gas cutoff valve | |
|
|
| is open. | |
| E. Blown fuse on ignition module or | E. Replace fuse per instructions in | ||
| interface board (units w/electronic |
| Section 6.6 of this manual. | |
| ignition only). |
|
| |
|
| F. | If available, substitute controller | |
|
|
| known to be good for suspect | |
| F. Failed controller. |
| controller. If fryer operates | |
|
|
| normally, order replacement | |
|
|
| controller from FASC. | |
Solid state (analog) |
|
|
| |
controller power and |
| If available, substitute controller | ||
trouble lights on, but |
| |||
heat light is not, |
| known to be good for suspect | ||
| Failed controller. | controller. If fryer operates | ||
OR |
| normally, order replacement | ||
LED display shows |
| controller from FASC. | ||
|
|
| ||
. |
|
|
| |
|
| If available, substitute controller | ||
Unit stays in melt |
| known to be good for suspect | ||
Failed controller. | controller. If fryer operates | |||
cycle continuously. | ||||
|
| normally, order replacement | ||
|
| controller from FASC. | ||
|
| A. Disconnect unit from electrical | ||
| A. Temporary controller malfunction |
| power, wait at least one minute, | |
CM III will not go | caused by voltage surge. |
| reconnect unit to the power | |
|
| supply and turn controller on. | ||
into programming |
| B. | If available, substitute controller | |
mode. |
|
| known to be good for suspect | |
| B. Failed controller. |
| controller. If fryer operates | |
|
|
| normally, order replacement | |
|
|
| controller from FASC. |