2.Remove the paper hold-down ring (and if changing the filter paper, remove and discard the used filter paper). Remove the filter screen and clean the crumb tray, hold-down ring, filter screen, and pan with a solution of hot water and dishwashing detergent, ensuring that all breading and food particles are removed from the pan. Ensure the pan is dried completely. Allow the screen to dry completely before reinstalling.

3.After verifying that the metal filter screen is in the bottom of the pan, lay a sheet of filter paper over the top of the pan, overlapping on all sides.

4.Position the hold-down ring over the filter paper and lower the ring into the pan, allowing the paper to fold up around the ring as it is pushed to the bottom of the pan, then sprinkle filter powder over the filter paper. (For powder quantity, see the filter powder manufacturer’s instructions.)

5.Replace the crumb tray in the filter pan, close the cover, and push the filter pan back into the fryer, positioning it all the way to the back of the cabinet.

4-3

Image 26
Contents Hour Service Hotline Series Gas FryersCanada Page Series GAS Fryers Table of Contents Applicability and Validity Parts Ordering and Service InformationSeries GAS Fryers General Information Retain and Store this Manual in a Safe Place for Future USEEquipment Description Safety InformationEuropean Community CE Specific Information Installation, Operating, and Service Personnel DefinitionsShipping Damage Claim Procedure What to do if your equipment arrives damagedClearance and Ventilation Series GAS Fryers Installation InstructionsGeneral Installation Requirements National Code Requirements Electrical Grounding RequirementsCaster/Leg Installation FCC CompliancePage Non-CE Standard For Incoming Gas Pressures CE Standard For Incoming Gas PressuresCE Standard CE Standard Burner Manifold Gas Pressures Page Non-CE Gas Conversion Kits Robertshaw Gas Valves Converting to Another Gas TypeDual-Vat Honeywell Gas ValvesCE and Non-CE Gas Conversion Instructions Lighting the Pilot on NON-EUROPEAN NON-CE Fryers Accessing the PilotSeries GAS Fryers Operating Instructions Pilot Button OFF Button For units equipped with other than Thermostat Controls Placing the Fryer Into OperationFor units equipped with Thermostat Controls Boiling-Out the FrypotPage Controller Operation and Programming Series GAS Fryers Filtration Instructions Page Page Snap the Power Shower into the frypot Page Page Daily Checks and Services Series GAS Fryers Preventive MaintenanceFryer Preventive Maintenance Checks and Services Weekly Checks and ServicesClean Detachable Parts and Accessories Quarterly Checks and ServicesDrain and Clean Frypot Check Computer Magic III Set Point Accuracy Clean Gas Valve Vent TubeCheck Thermostat Controller Thermostat Calibration Fryer SEMI-ANNUAL Checks and ServicesCheck Burner Manifold Pressure Built-In Filtration System Page Series GAS Fryers Operator Troubleshooting IntroductionProblem Probable Causes Corrective Action Probable Causes Corrective Action Troubleshooting Fryers with Thermostat ControlsProblem Troubleshooting Abnormal Burner Operation Troubleshooting the Built-In Filtration SystemOr the transfer is Pump starts, but noTransfer takes place Very slowPower Shower is not Spraying properlyReplacing the Controller or Controller Wiring Harness This page Intentionally Left Blank Service Hotline