Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or shortening.

Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.

Verify that the burner manifold pressure is in accordance with that specified on the appliance’s rating plate.

Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that probe guards are present and properly installed.

Verify that component box components (i.e. computer/controller, transformers, relays, interface boards, etc.) are in good condition and free from oil migration build-up and other debris. Inspect the component box wiring and verify that connections are tight and that wiring is in good condition.

Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and functioning properly.

Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot insulation is in serviceable condition.

Verify that wiring harnesses and connections are tight and in good condition.

Built-In Filtration System

Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.

Verify that all O-rings and seals (including those on the Power Shower and on quick-disconnect fittings) are present and in good condition. Replace o-rings and seals if worn or damaged.

Check filtration system integrity as follows:

With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the cooking oil/shortening (or that gurgling is heard from the Power Shower port) of the associated frypot..

Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot (or no gurgling should be heard from the Power Shower ports).

5-5

Image 34
Contents Hour Service Hotline Series Gas FryersCanada Page Series GAS Fryers Table of Contents Applicability and Validity Parts Ordering and Service InformationSeries GAS Fryers General Information Retain and Store this Manual in a Safe Place for Future USEEuropean Community CE Specific Information Safety InformationEquipment Description Installation, Operating, and Service Personnel DefinitionsShipping Damage Claim Procedure What to do if your equipment arrives damagedGeneral Installation Requirements Series GAS Fryers Installation InstructionsClearance and Ventilation National Code Requirements Electrical Grounding RequirementsCaster/Leg Installation FCC CompliancePage Non-CE Standard For Incoming Gas Pressures CE Standard For Incoming Gas PressuresCE Standard CE Standard Burner Manifold Gas Pressures Page Non-CE Gas Conversion Kits Robertshaw Gas Valves Converting to Another Gas TypeDual-Vat Honeywell Gas ValvesCE and Non-CE Gas Conversion Instructions Series GAS Fryers Operating Instructions Accessing the PilotLighting the Pilot on NON-EUROPEAN NON-CE Fryers Pilot Button OFF Button For units equipped with other than Thermostat Controls Placing the Fryer Into OperationFor units equipped with Thermostat Controls Boiling-Out the FrypotPage Controller Operation and Programming Series GAS Fryers Filtration Instructions Page Page Snap the Power Shower into the frypot Page Page Daily Checks and Services Series GAS Fryers Preventive MaintenanceFryer Preventive Maintenance Checks and Services Weekly Checks and ServicesDrain and Clean Frypot Quarterly Checks and ServicesClean Detachable Parts and Accessories Check Thermostat Controller Thermostat Calibration Clean Gas Valve Vent TubeCheck Computer Magic III Set Point Accuracy Check Burner Manifold Pressure SEMI-ANNUAL Checks and ServicesFryer Built-In Filtration System Page Series GAS Fryers Operator Troubleshooting IntroductionProblem Probable Causes Corrective Action Problem Troubleshooting Fryers with Thermostat ControlsProbable Causes Corrective Action Troubleshooting Abnormal Burner Operation Troubleshooting the Built-In Filtration SystemOr the transfer is Pump starts, but noTransfer takes place Very slowPower Shower is not Spraying properlyReplacing the Controller or Controller Wiring Harness This page Intentionally Left Blank Service Hotline