Programming special functions
3.Selecting an economy interim rinse (only for "Rapid" program)
^Turn the program selector to "STOP".
^Turn the machine off.
^Press and hold the "Display" and "Start" buttons, at the same time turn the machine on with the "On / Off" button.
The display shows the current program status "P...".
The "Fill/Drain" indicator lights.
^Press the "Extra Drying" button once. "E01" (programming level 1) is displayed.
^Turn the program selector to "Rinse". "40" or "41" is displayed.
"40" = without economy interim rinse "41" = with economy interim rinse
^Press "Display" to change from "40" to "41" or vice versa.
^Press the "Start" button. "SP" is displayed.
^Press the "Start" button again. The change has been saved.
Value set:
4.Venting and setting the dosage on "DOS modules G 60 and C 60" (optional extra)
^Set the dosage selector on the
^Turn the program selector to "STOP".
^Turn the machine off.
^Press and hold the "Display" and "Start" buttons, at the same time turn the machine on with the "On / Off" button.
The display shows the current program status "P...".
The "Fill/Drain" indicator lights.
^Press "Extra Drying" twice. "E02" (programming level 2) is displayed.
Venting the dispensing system:
^Turn the program selector to "Rinse". "do1" is displayed.
^Press "Display" for 90 secs. The dosage system is vented.
If only venting is required:
^Turn the machine off with On / Off
Immediately: Start the "Rinse" program, so that after venting any agents in the wash cabinet are diluted before being drained away.
30