Plumbing
Connection to the water inlet
,Water in the machine is not suitable for drinking.
^The machine must be connected to the water supply in accordance with local and national regulations.
^The machine is constructed to comply with Canada regulations, and may be connected to a suitable supply without an extra
^The water pressure (flow rate) must be a minimum of 7.25 - 145 psi.
If the water pressure (flow rate) is below 29 psi the fill time is automatically extended.
The maximum permitted static pressure is 145 psi.
If the water pressure is not in the range of 7.25 - 145 psi the "Fill/Drain" indicator may come on and the fault code "F2 E" will show in the display. Please contact the Miele Service Department.
^The machine is supplied as standard for connection to a cold (coded blue) and a hot (coded red) water supply up to a max. temperature of 158°F (70 °C).
The inlet hoses should be connected to the cold and hot water supplies.
If there is no hot water connection the hot water inlet hose marked red should also be connected to a cold water supply.
^Valves with 3/4 inch male threads are to be provided on site. They should be easily accessible so that the water supply can be turned off when the machine is not in use.
^The DN 10 inlet hose is approx. 5' 7 " (1.7 m) long ending in a 3/4 inch female thread. Do not remove the inlet filters.
^Large surface area filters are enclosed in the kit supplied with the machine for installation between the valve and the inlet hose
(see illustration in "Machine Care - Cleaning the filters in the Water inlet").
,The inlet hose must not be shortened or damaged in any way.
^See also the supplied installation diagram.
51