What to do if ... |
| ? |
| |
Error | Message on display | Possible cause | Remedy |
|
|
|
|
|
|
E01 | Not enough water | Water tap closed | Open water tap |
|
|
|
|
|
|
|
| Solenoid valve dirt filter contaminated | Remove and clean filter |
|
|
|
|
|
|
|
| Solenoid valve fault | Call customer service |
|
|
|
|
|
|
E02 | Connection area | Connection area ventilation fault | Allow Combi to cool, or continue |
|
| temperature too high | Air supply blocked | cooking at a lower oven |
|
|
|
| temperature, and call customer |
|
|
|
| service |
|
E03 | Fan malfunction | Motor temperature monitor triggered, | Call customer service |
|
|
| external failsafe triggered |
|
|
|
| Fan motor fault | Call customer service |
|
E04 | Connection area fan | Auxiliary fan fault | Call customer service |
|
| malfunction |
|
|
|
E05 | No gas | Gas supply interrupted | Open gas valve |
|
E11/E21 | Excess temperature in oven | Excess oven temperature | Call customer service |
|
| or oven sensor failure |
|
|
|
| Oven sensor fault | Call customer service |
| |
|
|
| ||
|
|
|
|
|
E13/E23 | Excess temperature in | Steam generator sensor fault | Call customer service |
|
| steam generator or steam |
|
|
|
| generator sensor failure |
|
|
|
E15/E25 | Excess temperature of | Water tap closed | Open water tap |
|
| condenser or condenser | Excess temperature in condenser via | Connect appliance to cold water, |
|
| sensor failure | hot water connection | restart |
|
|
| Solenoid valve dirt filter contaminated | Remove and clean filter |
|
|
| Solenoid valve fault | Call customer service |
|
|
| Condenser sensor fault | Call customer service |
|
E22 | Core temperature sensor | Core temperature sensor fault | Set cooking mode with time, |
|
| fault |
| and call customer service |
|
E24 | Bypass sensor failure | Bypass sensor fault | Call customer service |
|
E26 | Steam generator safety | Safety temperature limiter sensor fault | Call customer service |
|
| temperature limiter sensor | in steam generator |
|
|
| failure |
|
|
|
E27 | Excess temperature of | Steam generator dirty | Descale |
|
| steam generator heater |
|
|
|
E29 | Ground connection of sensor | Temperature sensor fault | Call customer service |
|
E33 | Steam generator heater error | Steam generator heater fault | Call customer service |
|
E34 | Steam generator pump error | Steam generator pump fault | Call customer service |
|
E80/E95/E96 | ID error / software error / | Control fault | Call customer service |
|
| connection fault |
|
|
|
E82 | Working parameter error | Problems during switch between °C / F | Check settings in Cookbook or |
|
|
|
| check °C/F in settings |
|
Low agent | No cleaner pressure | Cleaner canister or nozzle rinsing fluid | Fill canister |
|
pressure! |
| agent empty |
|
|
|
| Pump fault | Call customer service |
|
84