This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram. The Quickchiller must be properly grounded in accordance with the National Electrical Code and applicable local codes. Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific Quickchiller model. For supply connections, locate the wire size listed in this manual.
Before operating the chiller, check all cable connections in the electrical connection area for tightness since connections can loosen during transport.
NOTE: After electrical connections have been completed, operate the appliance in any chilling mode for a period of 15 minutes and recheck the main power connections at the terminal block to make certain they remain tight.
D A N G E R
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
DANGER
ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
ELECTRICAL SPECIFICATIONS
voltage | phase | cycle/hz |
|
|
|
|
| |
|
|
|
|
|
| |||
| 1 ph | 50/60 Hz |
|
|
|
|
| |
Recommended circuit amperage: | 20 amps | 20 amps | 30 amps | 40 amps | 60 amps | |||
Recommended wire size: | 12/2 w.g. | 12/2 w.g. | 10/2 w.g. | 8/2 w.g. | 6/2 w.g. | |||
|
|
|
|
|
|
|
| |
|
|
| n o c o r d a n d p l u g |
|
| |||
|
|
|
|
|
|
|
| |
voltage | phase | cycle/hz | ||||||
|
|
|
|
|
| |||
3 ph | 50/60 Hz | not available | not available | not available | 20 amps | 40 amps | ||
Recommended circuit amperage: | ||||||||
|
|
| ||||||
Recommended wire size: |
|
|
| 12/3 w.g. | 8/3 w.g. | |||
|
|
|
|
|
|
|
| |
| 3 ph | 50/60 Hz |
|
|
|
|
| |
Recommended circuit amperage: | not available | not available | 30 amps | not available | 30 amps | |||
Recommended wire size: |
|
| 10/2 w.g. |
| 10/2 w.g. | |||
|
|
|
|
|
|
|
| |
|
|
| n o c o r d a n d p l u g |
|
| |||
|
|
|
|
|
|
|
| |
voltage | phase | cycle/hz | ||||||
REMOTE COMPRESSOR |
|
|
|
|
| |||
(Cabinet Only) |
|
|
|
|
|
| ||
| 1 ph | 50/60 Hz | not available | not available | not available | 20 amps | 30 amps | |
Recommended circuit amperage: |
|
|
| 12/2 w.g. | 10/2 w.g. | |||
Recommended wire size: |
|
|
|
|
| |||
|
|
| n o c o r d a n d p l u g |
|
| |||
|
|
|
|
|
|
|
|
Wire diagrams are located near the top of the unit, close to the compressor or control panel.