Alto-Shaam QC-3/QC-20/QC-40/QC-50/QC-50 Remote/QC-100/Qc-100 Remote manual Operationt I T L E

Page 23

OPERATIONT I T L E

ADVANCEDSUB TITLE OPERATION

USER SETTINGS

CHANGING USER SETTINGS

Starting from the off position, press the power key on. The Alto-Shaam name will illuminate and the SELECTION SCREEN will appear on the display. The compressor will become energized and will begin to operate if required by the sensors.

Press the PROGRAM key. The display will indicate the User Settings each time the Program key is pressed.

USER SETTINGS

1.

Start Manual Defrost

7.

Default Hold Temperature

2.

Defrost Frequency

8.

HACCP Address

3.

Language

9.

Probe Verification

4.

Date - YYYY/MM/DD

10.

Presets

5.

Time - HH:MM

11.

Chill Modes

6.

°F/°C - Fahrenheit/Celsius

12. Factory Reset

Press the up 5or down6arrow keys to select the desired User Setting.

Press the right4or left3arrow keys to change the value.

Press the PROGRAM key to save settings and return to the SELECTION SCREEN.

6.°F/°C - Fahrenheit/Celsius

The display will indicate a choice between Celsius and Fahrenheit for Quickchiller temperature display readings. Press the right4or left3arrow key to toggle the setting.

7.HOLD DEFAULT

The display will indicate the default HOLD temperature. Press the right4or left3arrow key to increase or decrease the default holding temperature between a range of -5°F to +40°F (-21°C to +4°C).

8.HACCP ADDRESS

The display will indicate the HACCP Address Number. This item allows the operator to assign a specific identifying number (1 to 247) to the individual

Quickchiller as part of a serial communication interface for the web-based, HACCP with Kitchen Management software package option. Press the right4or left3arrow key to increase or decrease the number.

9.PROBE VERIFICATION

With the probe verification selected, press the Start key to enter the probe verification mode.

The display will show the offset and the temperature of:

Top Probe (where applicable)

Middle Probe (where applicable)

Bottom Probe (where applicable)

PROGRAMMING USER SETTINGS

1. START MANUAL DEFROST

Select Start Manual Defrost and press the START/STOP key to initiate a manual defrost cycle. The defrost cycle will complete operation when the temperature of the coil or coils reach set- point values or after a period of 20 minutes, whichever occurs first.

2.DEFROST FREQUENCY

The display will indicate the length of time necessary to accrue before the Fan Timer triggers an automatic defrost cycle. This period of time can be adjusted by pressing the right4or left3arrow keys to to increase or decrease automatic defrost cycle time (4-10 hours).

3.LANGUAGE

The display will indicate the currently selected language. Press the right4or left3arrow key to select English, Spanish, or French as the language of choice.

4.DATE

The display will indicate YEAR, MONTH, and DAY OF MONTH (YYYY/MM/DD). Press the up5or down6 arrow key to select the date, time, and day, and the right4or left3arrow key to increase or decrease the numbers as required.

5.TIME

The display will indicate the current TIME of day (HH:MM). Press the up5or down6arrow key to select the hours or minutes and the right4or left3arrow key to increase or decrease the numbers as required.

If probe calibration is needed, place the probe in a glass of ice-water and let the probe settle in temperature. The temperature in the glass should be 32°F (0°C).

To calibrate, Press up5or down6arrow key to adjust between the probes, and the right4or left3arrow keys to adjust the calibration value.

Press the PROGRAM key to exit probe calibration mode.

10.PRESETS (0=unlocked, 1=locked)

If the presets are locked, pressing start on the desired preset will skip the mode overview and will start immediately. Factory default

is locked.

11.CHILL MODES (0=unlocked, 1=locked)

If the chill modes are locked, pressing the chill mode button will skip the mode overview and will start immediately. Factory default

is unlocked.

12.FACTORY RESET

Resets all presets and user-defined settings to factory default settings. Warning: Pressing Factory Reset will erase all User Settings and Presets programmed by the user. All custom User Settings and Presets will need to be reprogrammed.

QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 2 1 .

Image 23
Contents Installation Wire Diagrams P a C K I N G L I V E R YN G E R Safety Procedures PrecautionsUnit must not be tipped on its side At any time InstallationInstallation Site InstallationDrainage Installation RequirementsWater Drainage Door SealTrolley Guide Installation Trolley Guide InstallationQC-3 Siteub TitleinstallationS Ttailtllaet I O N R404a Refrigerant S Ttailtllaet I onQC-20 1626mm x 1143mm x 1143mmApproximately 144 lb 65 kg maximum QC-4044 x 47 x 79 1118mm x 1194mm x 2007mm 404a RefrigerantQC-50 QC-50 Remote QC-100 Remote QC-100Casters, 5 127mm Optionssub Titleand AccessoriesModel QC-3 QC-20 QC-40 QC-50 QC-100380-415VAC 50/60 Hz Electrical SpecificationsElectricalsub Title 208-240VAC 50/60 HzModified COOK-CHILL Operations Etritaltei O NOperating Introduction Traditional COOK-SERVE KitchensInitial Quickchiller Operation Chill Processing CyclesQuickchiller Operation Modes Door Power OutageAdditional Information FAN OperationControl Panel Identification Manual Operation Basicsub TitleoperationHold Temp When in the Hold Temp Mode After a Chill ModeAdvancedsub Title Operation Chilling by Probe Factory Default SET PointsWhen in the Hold Temp Mode After Chilling by Probe Chilling by TimeE R a T I O N Preset Program OperationProgramming Presets Preset SelectionsOperationt I T L E User SettingsAutomatic Defrost Time & Temperature GuidelinesFood Probe USE User InformationPortioning & Packaging Foodsub Titlehandling GuidelinesProduct Covering D I V I D U a L P a N C a P a C I T I E S Quickchiller PAN CapacityI C K C H I L L E R P a N C a P a C I T Y C H a R T Product Capacity PER PANDesserts PAN Size ›Breakfast Items StarchesCleaning Materials Care Andti T CleaningeCleaning and Preventive Maintenance Cleaning AgentsMonthly Compressor & Condenser Maintenance Interior CleaningExterior Cleaning Food Trolley CleaningO U B Lteitslheo O T I N G Model QC-3 Control Etritvlice EModel QC-3 Coil Etritvlice EModel QC-20 Control Model QC-20 Coil Model QC-20 Condenser Model QC-40 Model QC-40 Control Model QC-50, QC-100 Control Model QC-100 Coil Model QC-50, QC-100 FAN Model QC-50, QC-100 BreakerModel QC-50 Remote Remote condensor connection Model QC-50, QC-100 RemoteModel QC-3 Wiring Model QC-20 Wiring Model QC-40 Wiring Model QC-50 Wiring 1PH 3PH Model QC-100 Wiring 1PH 3PH Page Page Page Page Page Page Page Page Page Page Page Page Page Limited Warranty