I N S T A L L A T I O N
D A N G E R
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
Position the Quickchiller
to allow sufficient air ventilation through the condensing unit(s). The rear of unit should be no closer than 6" (152mm) to any wall or structure.
Avoid installing the chiller immediately adjacent to fryers, charbroilers, or any other equipment producing
grease laden air; heat producing equipment such as ovens and
ranges; and steam discharging equipment such as steamer ovens and kettles. Do not locate the Quickchiller in direct sunlight.
Allow sufficient front clearance for serviceability and for easy maneuvering of food trolleys in and out of the cabinet.
INSTALLATION
Prior to moving the Quickchiller to the installation site, check the dimensions of doors, passageways, and ceiling heights in the areas through which the cabinet must be moved. Also check the turning radius if the cabinet must be moved around an existing structure. The use of a fork lift or pallet lift truck is required for moving and leveling most Quickchiller models.
NOTE: In certain instances, it may be necessary to remove doors and door hardware to negotiate tight spaces.
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
SITE INSTALLATION
CLEARANCE REQUIREMENTS
BACK: 6" (152mm) | TOP: 6" (152mm) |
SIDES: 4" (102mm) minimum at both sides.
18" (457mm) minimum clearance from heat producing equipment.
INSTALLATION REQUIREMENTS
Unit must NOT be tipped on its side
at any time.
Tipping will cause damage to the unit
and void the warranty.
One (1) Floor Drain: 1/2" (12,7mm) diameter
—Appliance must be installed level.
—The appliance must not be installed in any area where it may be affected by steam, grease, dripping
water, extreme temperatures, or any other severely adverse conditions.
In order to maintain standards established by the National Sanitation Foundation, all counter mounted equipment must be sealed to the counter with a NSF listed silicone sealant.
Effective from date of shipment. (excludes labor)
QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 3 .