O P ETRITALTEI O N
CHILL PROCESSING CYCLES
The
The high velocity cold air produced by the Quickchiller removes insulating layers of warm moist air that surrounds hot products. The rapid removal of these insulating layers of heat reduces food temperatures significantly faster than any other method of temperature reduction and provides enhanced food safety.
Because the basic performance of the Quickchiller relies on high velocity air movement around each container of food, it is important to load the food by placing pans directly into the pan slides. Always use the pan slides to support the edges of 12" x 20" steam table pans (GN 1/1). Use a wire shelf for pan support when using 18" x 26" sheet pans; 12" x 10" steam table pans (GN 1/2); loaf pans; entree plates; and other small containers.
CAUTION
TO MAINTAIN SANITATION
CONTROL, ALL FOODS FOR
PROCESSING MUST BE AT A
TEMPERATURE ABOVE 140°F (60°C)
AND MUST BE TIGHTLY COVERED.
QUICKCHILLER OPERATION MODES
➤PROCESSING WITH THE USE OF PROBES
Probe usage provides chill or frozen food processing activation and termination through use of a food probe or probes inserted into the center of the food. The cycle is automatically terminated when the center of the food reaches the probe sensing temperature set by the operator. In units with multiple probes, all probes much reach the sensing temperature set by the operator to trigger automatic termination of the cycle.
➤PROCESSING BY TIME
The time mode provides processing activation and termination based on a timed cycle selected by the operator. Upon expiration of the timed cycle, the cabinet automatically reverts to the designated holding cycle temperature.
➤HOLDING
Following processing completion, a holding cycle maintains the temperature to safely hold foods after processing. The holding cycle will also maintain a holding compartment temperature between processing cycles.
INITIAL QUICKCHILLER OPERATION
PRECHILLING THE CABINET
The Quickchiller should be prechilled prior to placing hot foods into the cabinet. In models equipped with a
Optional Prechill Sealing Strip
5008856
QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 1 4 .