CONTROL ERROR DISPLAYS

control display

action required

 

 

Real Time Clock Bad

This is likely caused by the unit having been unplugged for an extended

E-60: REAL TIME CLOCK DEFAULTS LOADED,

amount of time. The data stored in the Real-Time Clock has been reset to

VERIFY CORRECT TIME, POWER CYCLE UNIT TO

the factory default values. Contact service if problem persists.

CLEAR THIS MESSAGE.

 

 

 

Real Time Clock Not Detected

Real Time Clock not detected. Contact service if problem persists.

E-61: REAL TIME CLOCK NOT DETECTED.

 

POWER CYCLE UNIT AND CALL FOR

 

SERVICE IF THE PROBLEM PERSISTS.

 

 

 

Button Stuck

This error message indicates that a button is stuck. Check all buttons.

E-90: BUTTON STUCK. CHECK ALL BUTTONS AND

Error will clear when the problem has been solved. Contact service is

ERROR WILL CLEAR WHEN THE PROBLEM HAS

problem persists.

BEEN RESOLVED

 

 

 

Using Default Function Values

This error message indicates the control memory is not correctly reading

E-80 - EEPROM ERROR

user-set values. The Quickchiller will remain operational but the user

USING DEFAULT FUNCTION VALUES

defined settings will be reloaded to the default values. The control will

 

revert to factory default settings and will require operator modification

 

each time the unit is used. Call Service. Acknowledge error by pressing

 

the power button.

 

 

Probe Open/Shorted

This error message indicates a problem with the probe identified within the

PROBE N* OPEN -OR- PROBE N* SHORTED

display. The Quickchiller will operate normally in the Time mode but will

CALL FOR SERVICE

not operate in the Probe mode. Call service.

 

*N signifies probe number that is shorted: 1= top, 2= middle, 3= bottom

 

 

Cavity Open Shorted

This error message indicates a problem with the interior cavity sensor. The

CAVITY SENSOR OPEN OR SHORTED.

Quickchiller will not operate in any operational mode. Call service.

CALL FOR SERVICE

 

 

 

Coil Open Shorted

This error message indicates a problem with the display identified coil

COIL N* OPEN OR COIL N* SHORTED

sensor. The Quickchiller will remain operational but will extend the

CALL FOR SERVICE

defrost cycle to the full period of 20 minutes. Call service.

 

*N signifies coil number that is shorted.

 

 

Bad Calibration

Calibration bad. Call service.

E-81: BAD CALIBRATION. PLEASE CALL SERVICE

Note: Display will signify PASS where calibration is good, or FAIL

AD1-0=(PASS) (FAIL) AD1-1=(PASS)(FAIL)

AD2-0=(PASS)(FAIL) AD2-1=(PASS)(FAIL)

where calibration is bad.

AD3-0=(PASS)(FAIL) AD3-1=(PASS)(FAIL)

 

 

 

Requires Calibration

Requires Calibration. Call service.

E-82: REQUIRES CALIBRATION.

 

PLEASE CALL SERVICE

 

 

 

Power Failure

Power has been off. Press Program to acknowledge.

POWER WAS OFF FOR HH:MM

NOTE: If such an event has occurred, it is strongly recommended

PRESS PROGRAM TO ACKNOWLEDGE

that you ensure the food is safe for consumption according to

 

local health regulations.

 

 

QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 2 8 .

Image 30
Contents Installation Wire Diagrams L I V E R Y P a C K I N GSafety Procedures Precautions N G E RSite Installation InstallationInstallation Unit must not be tipped on its side At any timeDoor Seal Installation RequirementsWater Drainage DrainageTrolley Guide Installation Trolley Guide InstallationSiteub Titleinstallation S Ttailtllaet I O NQC-3 1626mm x 1143mm x 1143mm S Ttailtllaet I onQC-20 R404a Refrigerant404a Refrigerant QC-4044 x 47 x 79 1118mm x 1194mm x 2007mm Approximately 144 lb 65 kg maximumQC-50 QC-50 Remote QC-100 QC-100 RemoteQC-3 QC-20 QC-40 QC-50 QC-100 Optionssub Titleand AccessoriesModel Casters, 5 127mm208-240VAC 50/60 Hz Electrical SpecificationsElectricalsub Title 380-415VAC 50/60 HzTraditional COOK-SERVE Kitchens Etritaltei O NOperating Introduction Modified COOK-CHILL OperationsChill Processing Cycles Quickchiller Operation ModesInitial Quickchiller Operation FAN Operation Power OutageAdditional Information DoorControl Panel Identification Basicsub Titleoperation Manual OperationWhen in the Hold Temp Mode After a Chill Mode Advancedsub Title OperationHold Temp Chilling by Time Factory Default SET PointsWhen in the Hold Temp Mode After Chilling by Probe Chilling by ProbePreset Selections Preset Program OperationProgramming Presets E R a T I O NUser Settings Operationt I T L EUser Information Time & Temperature GuidelinesFood Probe USE Automatic DefrostFoodsub Titlehandling Guidelines Product CoveringPortioning & Packaging Product Capacity PER PAN Quickchiller PAN CapacityI C K C H I L L E R P a N C a P a C I T Y C H a R T D I V I D U a L P a N C a P a C I T I E SStarches PAN Size ›Breakfast Items DessertsCleaning Agents Care Andti T CleaningeCleaning and Preventive Maintenance Cleaning MaterialsFood Trolley Cleaning Interior CleaningExterior Cleaning Monthly Compressor & Condenser MaintenanceO U B Lteitslheo O T I N G Etritvlice E Model QC-3 ControlEtritvlice E Model QC-3 CoilModel QC-20 Control Model QC-20 Coil Model QC-20 Condenser Model QC-40 Model QC-40 Control Model QC-50, QC-100 Control Model QC-100 Coil Model QC-50, QC-100 Breaker Model QC-50, QC-100 FANModel QC-50 Remote Model QC-50, QC-100 Remote Remote condensor connectionModel QC-3 Wiring Model QC-20 Wiring Model QC-40 Wiring Model QC-50 Wiring 1PH 3PH Model QC-100 Wiring 1PH 3PH Page Page Page Page Page Page Page Page Page Page Page Page Page Limited Warranty