6WDLQOHVVVWHHODSSOLDQFHV To prevent corrosion, avoid using sponge cloths or wash them out thoroughly several times before using for the
¿UVWWLPH
Filters 7KH¿OWHUVNHHSODUJHIRUHLJQREMHFWVLQWKHULQVLQJZDWHUDZD\IURPWKH SXPS7KHVHIRUHLJQREMHFWVPD\RFFDVLRQDOO\EORFNWKH¿OWHUV
7KH ¿OWHU V\VWHP FRQVLVWV RI D FRDUVH ¿OWHU D ÀDW ¿QH ¿OWHU DQG D
PLFUR¿OWHU
| $IWHUHDFKZDVKLQJF\FOHFKHFNWKH¿OWHUVIRUUHVLGXH |
| 8QVFUHZ¿OWHUF\OLQGHUDVLOOXVWUDWHGDQGWDNHRXW¿OWHUV\VWHP |
| 5HPRYHDQ\UHVLGXHDQGFOHDQ¿OWHUVXQGHUUXQQLQJZDWHU |
| 5HLQVWDOO ¿OWHU V\VWHP LQ UHYHUVH VHTXHQFH DQG HQVXUH WKDW WKH |
| DUURZPDUNVDUHRSSRVLWHHDFKRWKHUDIWHUFORVLQJWKH¿OWHUV\VWHP |
CAUTION 7RDYRLGLQMXU\GRQRWUHDFKLQWRWKHODUJHREMHFWWUDSZLWK\RXU ¿QJHUV7KHODUJHREMHFWWUDSFRXOGFRQWDLQVKDUSREMHFWV
6SUD\DUPV
Limescale and contaminants in the rinsing water may block nozzles and bearings on the spray arms. Using the water softening system may reduce this.
Check outlet nozzles on the spray arms for blockages. Unscrew the upper spray arm.
Remove the lower spray arm.
:DVWHZDWHUSXPS
/DUJHIRRGUHPQDQWVLQWKHULQVLQJZDWHUQRWUHWDLQHGE\WKH¿OWHUVPD\ block the waste water pump. The rinsing water does not get pumped
RXWDQGFRYHUVWKH¿OWHU
,QWKLVFDVH
Disconnect the appliance from the power supply.
5HPRYHWKH¿OWHUV
Scoop out water, use a sponge if required.
Using a spoon, pry off pump cover(as illustrated) until it clicks, then
JULSWKHFRYHUE\WKHOXJDQG¿UVWSXOOLWXSZDUGVXQWLOLWUHVLVWVDQG then pull it out forwards.
Check inner compartment and remove any foreign objects. Place cover in the original position, press down and engage.
,QVWDOO¿OWHUV
1 |
2 |
1 |
2 | 3 |
Klick |
|