INSTALLATION & OPERATIONAL SELV MANUAL
2.6 OPTIONAL CORD SET & PLUG and RESTRAINT CABLE
If your appliance was not equipped with an optional cord set and plug, field connection to electrical power supply will be required. Adhere to all local or national codes and warnings from (see section 2.5) when making field connections to mains. Use the table above to determine conductor rating, and
1.Remove the fryer entrance box cover, Figure 1.5.1.
2.Insert power cable/conduit through hole in fryer cabinet, Figure 1.5.2. Use care when routing power cable/conduit through the fryer to not interfere with actuator movement.
3.Referring to figure 1.5.3, Install cable strain relief in housing cutout (1). Attach power cable wires to terminal block (2) per connection diagram on fryer door.
4.Attach a movement restraint cable assembly to any fryer that is not connected with a cord and plug, Figure 1.5.4.
Figure 1.5.1 (Drain line removed for clarity)
Figure 1.5.3 Wire housing strain relief hole. 2” or 1.75” diameter
Figure 1.5.2
Insert flexible conduit through cabinet as shown to prevent contact with moving parts in fryer cabinet.
1
Figure 1.5.4: Fryers on casters, or installed with flexible conduit must have a restraint cable between the fryer, and substantial building structure to prevent strain on the electrical conduit.
10 |