SELV INSTALLATION & OPERATIONAL MANAUAL
13 TROUBLESHOOTING
13.1 POWER FAILURE
If electric power is removed for any reason, the appliance will shut down.
To restart the appliance, follow the appliance start up procedure in (See section 3.3.)
CAUTION
DO NOT attempt to operate this appliance during a power outage.
13.2 HIGH TEMPERATURE LIMIT
This appliance is equipped with a high temperature limit switch. The high temperature limit switch will stop the appliance from heating if the internal cook tank reaches an unsafe temperature. In the event that the high temperature limit has tripped, Please refer to the following procedure to reset the switch.
a.Turn the appliance off.
b.Allow the appliance time to cool to room temperature.
c.Add oil to the cook tank as needed.
d.Remove the access screw located under the basket support. Picture 1.
e.Use a small diameter tool ( 1/8” maximum) such as a small Philips screwdriver to press the reset button. Picture 2.
f.Install the Access cover screw.
g.The high limit switch is now reset and the appliance is ready for start up.
h.If the reset becomes tripped again, discontinue using the fryer, and call for service.
Picture 1
Use a flat screw driver to remove the screw marked “Reset Button”(Full pot shown). SELV14T reset buttons are under the outer Screws.
Picture 2
Use a small diameter rod (1/8” max.), or a Philips screwdriver to reach through the access hole and press the reset button.
WARNING
DO NOT add oil to the frryer until it has been given ample time to cool down. Failure to do so may result in damage to the appliance and/or injury to the operator.
13.3 DRAIN VALVE INTERLOCK
Your appliance is equipped with a drain valve interlock circuit to prevent the appliance from heating if the frypot drain valve is opened. Refer to the following procedure to resume operation after the drain valve interlock is tripped.
1.Turn the appliance OFF.
2.Close the tank drain valve and fill the tank with oil/shortening.
3.Turn the appliance ON.
31 |