11.2 TEMPERATURE CHECK

Use a high grade pyrometer or digital thermometer suitable for temperature up to 380°F (182°C). Place the thermometer in the oil above the tip of the fryer’s temperature probe with in 1” (2.54 cm) 25.4 mm). Be sure not to touch the heat tube since this will measure incorrect temperatures.

Check that the controllers set point and thermometer is within +/- 5°F (2.8°C). If your measurement are off, re-measure again before contacting an Authorized Service Company for further assistance.

12 ANNUAL/PERIODIC PREVENTATIVE MAINTENANCE AND INSPECTION

This section should ONLY be performed by a qualified service technician as part of a regular kitchen maintenance program. This inspection should take place a minimum of once a year by an Authorized Service Technician recommended by Pitco. It may be necessary perform this inspection more than once a year.

12.1.1SAFETY EVALUATION

Check power cord and plug.

Check all exposed wiring connections, switches, and indicator lights.

Check legs, casters, wheels, plate welds and ensure all nuts and bolts are secured.

12.1.2MECHANICAL INSPECTION

Check fry tank for shortening leaks and excessive oil build up

Check for oil migration (Clean as required)

Check hood drain cup, ensure that it is not dripping onto the appliance. Empty as necessary.

Check hood baffle for clean surface, oil/water condense can drip onto appliance.

Check drain/filtration system (if equipped) for leaks

Check for missing fryer parts.

Check for missing fasteners

12.1.3TEMPERATURE CONTROL SYSTEM

Check electrical connections and harnesses

Check temperature probes and limits for carbon build up and plating. Clean as required

Check proper mounting of probes and sensors and verify all fasteners are secure.

Check DVI Drain Valve Interlock drops out controller.

Check Controller/thermostat features to ensure they are functioning.

Check Temperature Calibration

12.1.4FILTER SYSTEM (IF EQUIPPED)

Check electrical connections and harnesses.

Check IEC power cords are fully engaged and secure.

Check for any air or shortening leaks and for excessive oil build-up.

Check O-Ring on filter pickup tube and replace as needed.

Check filter strainer on pickup tube.

Check operation of drain valve and DVI drain valve interlock.

Check operation of return oil valve and its pump switch.

Check all hardware in filter pan.

Check filter operation by filtering the fryers.

Check pump motor amp draw compare to nameplate amperage.

Check pump and motor; clean any excess oil from pump assembly.

Check all filter hoses for leaks and integrity.

29

L20-406 Rev 5 (3/14)

Image 29
Contents Reduced OIL Volume Frying System To the PURCHASER, Owner and Store Manager Table of Contents Routine Cleaning Theory of Operation Installation Checking and Unpacking Your NEW Appliance Installation Clearances General Installation RequirementsCaster and leg types Leveling the FRYER‐ LEGS/CASTERSRequirements Electrical Connections1 Drain line removed for clarity Optional Cord SET & Plug and Restraint CableInspection Ventilation and Fire Safety SystemsCooking Guidelines Filling the Cooking TankOperation Operational Features Drain Valve Handle Blue Pull to drain frypot Basic Operational FeaturesAppliance Start UP OIL TemperatureComputer Controller Operation Typical displays using key 4 as an example To View Current Settings for cook, shake, and hold timesTo perform a Boil Out operation Automatic Boil Entry Water DetectionTo Enter Programming Level 1 for the Store Manager To Set Cook TemperatureCook Time Shake TimeTo Exit Level 1 programming Hold Pre-AlarmTo Enter Programming Level 2 for the Store Manager Fahrenheit or Celsius DisplayBeeper Volume and Tone Password Change or Required?Recovery Test Value Language SelectionControl or Timer Right side of Dual Vat Control or Timer Left side of Dual or Single VatOther Displays Appliance ShutdownAutomatic OIL TOP System Option OIL Management Push Button OIL TOP OFF SystemFlush Hose Operation if equipped Cook Counter AdjustmentQuick Strain Filtering Filter Soon light flashing Clean Filter Parts Routine Cleaning Cleaning ScheduleStart of DAY Replacing the Filter Media if equippedInstallation & Operational Selv Manual Cleaning the Cabinet Daily Cleaning Instructions END of DAY Cleaning the Cook Tank Weekly Preventative Maintenance Filter Cleaning If EquippedBoil OUT Procedure Monthly Preventative MaintenanceANNUAL/PERIODIC Preventative Maintenance and Inspection Temperature CheckHeating Element Drain Valve Interlock Troubleshooting Power FailureHigh Temperature Limit Fryer Troubleshooting Chart Troubleshooting ChartsProblem Probable Causes Corrective Actions Filter TroubleshootingComputer & Digital Controller Displays Display Problems ActionFrying oil Problem-Solving Possible Cause Solution PROBLEM‐SOLVING ShorteningSelv Installation & Operational Manaual