INSTALLATION & OPERATIONAL SELV MANUAL
11.2 TEMPERATURE CHECK
Use a high grade pyrometer or digital thermometer suitable for temperature up to 380°F (182°C). Place the thermometer in the oil above the tip of the fryer’s temperature probe with in 1” (2.54 cm) 25.4 mm). Be sure not to touch the heat tube since this will measure incorrect temperatures.
Check that the controllers set point and thermometer is within +/- 5°F (2.8°C). If your measurement are off,
12 ANNUAL/PERIODIC PREVENTATIVE MAINTENANCE AND INSPECTION
This section should ONLY be performed by a qualified service technician as part of a regular kitchen maintenance program. This inspection should take place a minimum of once a year by an Authorized Service Technician recommended by Pitco. It may be necessary perform this inspection more than once a year.
12.1.1SAFETY EVALUATION
Check power cord and plug.
Check all exposed wiring connections, switches, and indicator lights.
Check legs, casters, wheels, plate welds and ensure all nuts and bolts are secured.
12.1.2MECHANICAL INSPECTION
Check fry tank for shortening leaks and excessive oil build up
Check for oil migration (Clean as required)
Check hood drain cup, ensure that it is not dripping onto the appliance. Empty as necessary.
Check hood baffle for clean surface, oil/water condense can drip onto appliance.
Check drain/filtration system (if equipped) for leaks
Check for missing fryer parts.
Check for missing fasteners
12.1.3TEMPERATURE CONTROL SYSTEM
Check electrical connections and harnesses
Check temperature probes and limits for carbon build up and plating. Clean as required
Check proper mounting of probes and sensors and verify all fasteners are secure.
Check DVI Drain Valve Interlock drops out controller.
Check Controller/thermostat features to ensure they are functioning.
Check Temperature Calibration
12.1.4FILTER SYSTEM (IF EQUIPPED)
Check electrical connections and harnesses.
Check IEC power cords are fully engaged and secure.
Check for any air or shortening leaks and for excessive oil
Check
Check filter strainer on pickup tube.
Check operation of drain valve and DVI drain valve interlock.
Check operation of return oil valve and its pump switch.
Check all hardware in filter pan.
Check filter operation by filtering the fryers.
Check pump motor amp draw compare to nameplate amperage.
Check pump and motor; clean any excess oil from pump assembly.
Check all filter hoses for leaks and integrity.
29 |