Pitco Frialator SELV14 Filter Troubleshooting, Problem Probable Causes Corrective Actions

Page 33

SELV INSTALLATION & OPERATIONAL MANAUAL

14.2 FILTER TROUBLESHOOTING

Problem

Probable Causes

Corrective Actions

 

Drain valve is not fully open

Press down on the drain valve handle and verify

Drain Valve is open; the

that it is fully open.

 

Use the clean out rod to clear the drain valve

oil is draining slowly or not

 

 

opening. If this doesn't clear the blockage, close

at all.

Drain is plugged with debris.

the drain valve and contact a qualified service

 

 

 

 

technician.

 

Red return valve handle is not

Pull on the red return valve handle to make sure

 

completely open.

it is completely open.

 

 

 

 

Filter circuit breaker is tripped

Reset the circuit breaker or press it to the on

Pump return handle is

or in the off position.

position.

Filter motor thermal overload

Push the red reset button on the end of the filter

pulled out, but no pumping

sound can be heard.

is tripped.

pump motor.

Filter power cord is unplugged

Check the power cord at the rear of the fryer

 

 

entrance box, and at the rear of the pump box

 

or loose.

and verify that the power cords are pushed all the

 

 

way into their receptacles.

 

Loose or defective sensor

Contact Authorized Service Company.

 

switch.

 

 

 

Dirty filter envelope

Change filter envelope.

Oil/shortening is returning

Pickup tube screen clogged.

Remove and clean pickup tube screen cap.

Filter pan not pushed in

 

to the tank slowly or not at

Push filter pan in.

all.

completely.

 

O-rings not sealing on pickup

Check and replace o-rings as needed.

 

 

tube.

 

 

Excessive air bubbles are

Pickup tube screen not tight.

Tighten pickup tube screen cap.

Pickup tube screen cap

Locate and install pickup tube screen cap.

in the oil being returned to

missing

 

the tank.

Filter pan not pushed in

Push filter pan in to complete connection.

 

completely

 

 

Oil/Shortening is cloudy

Filter envelope torn or

Change filter envelope.

damaged.

 

when returned to fry tank.

Low shortening temperature

Cloudiness should disappear when oil/shortening

 

 

is heated.

Drain valve is closed, but

Blue drain valve handle not

Verify that drain valve handle is completely

completely closed

closed.

the computer controller

Improperly adjusted or

 

still displays “DRAINING”

Contact Authorized Service Company.

 

defective drain switch.

 

33

L20-406 Rev 5 (3/14)

Image 33
Contents Reduced OIL Volume Frying System To the PURCHASER, Owner and Store Manager Table of Contents Routine Cleaning Theory of Operation Installation Checking and Unpacking Your NEW Appliance Installation Clearances General Installation RequirementsCaster and leg types Leveling the FRYER‐ LEGS/CASTERSRequirements Electrical Connections1 Drain line removed for clarity Optional Cord SET & Plug and Restraint CableInspection Ventilation and Fire Safety SystemsCooking Guidelines Filling the Cooking TankOperation Operational Features Drain Valve Handle Blue Pull to drain frypot Basic Operational FeaturesAppliance Start UP OIL TemperatureComputer Controller Operation Typical displays using key 4 as an example To View Current Settings for cook, shake, and hold timesTo perform a Boil Out operation Automatic Boil Entry Water DetectionTo Enter Programming Level 1 for the Store Manager To Set Cook TemperatureCook Time Shake TimeTo Exit Level 1 programming Hold Pre-AlarmTo Enter Programming Level 2 for the Store Manager Fahrenheit or Celsius DisplayBeeper Volume and Tone Password Change or Required?Recovery Test Value Language SelectionControl or Timer Right side of Dual Vat Control or Timer Left side of Dual or Single VatOther Displays Appliance ShutdownAutomatic OIL TOP System Option OIL Management Push Button OIL TOP OFF SystemCook Counter Adjustment Quick Strain Filtering Filter Soon light flashingFlush Hose Operation if equipped Clean Filter Parts Routine Cleaning Cleaning ScheduleStart of DAY Replacing the Filter Media if equippedInstallation & Operational Selv Manual Daily Cleaning Instructions END of DAY Cleaning the Cook TankCleaning the Cabinet Weekly Preventative Maintenance Filter Cleaning If EquippedBoil OUT Procedure Monthly Preventative MaintenanceANNUAL/PERIODIC Preventative Maintenance and Inspection Temperature Check Heating Element Troubleshooting Power Failure High Temperature LimitDrain Valve Interlock Fryer Troubleshooting Chart Troubleshooting ChartsProblem Probable Causes Corrective Actions Filter TroubleshootingComputer & Digital Controller Displays Display Problems ActionFrying oil Problem-Solving Possible Cause Solution PROBLEM‐SOLVING ShorteningSelv Installation & Operational Manaual